![Acute MSO 2000 Series Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/acute/mso-2000-series/mso-2000-series_manual_3047112052.webp)
52
皇晶科技股份有限公司
Acute Technology Inc.
Copyright
2018
Waveform search
is divided into four modes:
1. By Edge: Move the specified cursor according to the number of
Rising/Falling/Either edges (x1 ~ x4096) of the specified channel.
2. By Time: Move the specified cursor forward or backward to a certain amount of
time.
3. By Value Match: In search of displayed value content of the specified channel, if
the specified channel is a protocol, the text comparison will be used for the
search; if the specified channel is the bus or channel, the numerical comparison
will be used for the search.
4. Search Pulse Width: The waveform pulse widths meeting the conditions can be
searched on the specified channels. The single-cursor movement function on
the left side or the multiple-cursor movement function on the right side can be
used on any operation meeting or exceeding the conditions.
All of the above operations can be used to move a single cursor on the left or
multiple cursors on the right.
The starting point of the search is set to the current position of the selected cursor.