background image

14

FCC Information

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:

1- This device may NOT cause harmful interference, and

2- This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. 

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment 

generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, There is no guarantee that interference will not occur in a particular instal-

lation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and the receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. 

Such modifications could void the user authority to operate the equipment.

TEMPERATURE RANGE

Outdoor: -40

º

F to 158

º

F; -40

º

C to 70

º

C

Indoor: 32

º

F to 122

º

F; 0

º

C to 50

º

C

HUMIDITY RANGE

Outdoor: 1% - 99% RH (relative humidity)
Indoor: 1% - 99% RH (relative humidity)

WIRELESS RANGE

330 ft / 100 m 

depending on home construction materials

OPERATING FREQUENCY

433 MHz

POWER

Display: 5v power adapter (included) 

             3 x AA alkaline batteries 

(optional; not included)

Sensor: 2 x AA alkaline or lithium batteries 

(not included)

DATA REPORTING

Outdoor Data: 16 second updates

Indoor Data:  60 second updates

Specifications

Содержание 02038W

Страница 1: ...ion 2 Features Benefits Sensor 2 Features Benefits Display 3 Setup 5 Sensor Setup 5 Display Setup 6 Intelli Time Clock 7 Set the Time Date Units 7 Backlight Settings 7 Placement Guidelines 8 Using the...

Страница 2: ...play unit 2 Outdoor sensor 3 Power adapter 4 Instruction manual PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEI...

Страница 3: ...Pressure will self calibrate over a 14 day Learning Mode Manual Pressure Mode Indicates manually calibrated pressure 8 Moon Phase 9 Barometric Pressure Arrow icon indicates the direction the pressure...

Страница 4: ...up preferences 3 Setup Mode Button for setup preferences 4 Adjust Down Button for setup preferences 5 Battery Compartment 6 Reset Button Full reset to factory defaults 7 Battery Compartment Cover 8 Pl...

Страница 5: ...ies are not recommended The sensor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor fo...

Страница 6: ...n rechargeable batteries DO NOT short circuit the supply terminals Display Unit Setup Set the A B C Switch Locate the A B C switch inside the battery compartment Set the A B C switch to A B or C You m...

Страница 7: ...ng Time ON or OFF CLOCK HOUR CLOCK MINUTE CALENDAR MONTH CALENDAR DATE CALENDAR YEAR TEMPERATURE UNITS F or C PRESSURE UNITS inHg or hPa You will automatically exit SET MODE if no buttons are pressed...

Страница 8: ...a well covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accur...

Страница 9: ...4 hours by collecting data from the sensor in your backyard It generates a forecast with pinpoint accuracy personalized for your exact location OPERATION View the complete list of icons at www AcuRite...

Страница 10: ...r indoor and outdoor temperature and humidity Today s records automatically clear at 12 00am midnight every day To manually clear all of today s LOW recorded values press and hold the button for 2 sec...

Страница 11: ...h other for about 20 minutes to gain a strong connection Inaccurate forecast Weather Forecast icon predicts conditions for the next 12 to 24 hours not current conditions Has Learning Mode icon disappe...

Страница 12: ...ess the or buttons to calibrate the data value higher or lower from the actual reading 4 Press the button to confirm the calibration adjustment The icon will remain illuminated next to calibrated valu...

Страница 13: ...and the power adapter is unplugged To exit manual pressure mode and return to auto mode press and hold the button for at least 10 seconds Replace Intelli Time Battery Remove small screw to gain acces...

Страница 14: ...ned by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separ...

Страница 15: ...es are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liab...

Страница 16: ...ve owners Patent numbers 5 978 738 6 076 044 6 597 990 US 7 637 141 B2 Printed in China 02038 INST 113012 It s more than accurate it s AcuRite offers an extensive assortment of precision instruments d...

Отзывы: