background image

8

Placement for Maximum Accuracy

AcuRite sensors are sensitive to surrounding environmental conditions. Proper 

placement of both the display unit and outdoor sensor are critical to the 

accuracy and performance of this product.

Display Unit Placement

Place the display unit in a dry area free of dirt and dust. 

Display unit stands upright for tabletop use or is wall-

mountable.

Outdoor Sensor Placement

Sensor must be placed outside to observe outdoor conditions. 

Sensor is water resistant and is designed for general outdoor 

use, however, to extend its life place the sensor in an area 

protected from direct weather elements.
Hang the sensor using the integrated hang holes or hanger, or 

by using string (not included) to hang it from a suitable location, 

like a well covered tree branch. The best location is 4 to 8 feet 

above the ground with permanent shade and plenty of fresh air 

to circulate around the sensor.  

Important Placement Guidelines

• To ensure accurate temperature measurement, place units out of direct  

 

  sunlight and away from any heat sources or vents. 
• Display unit and outdoor sensor must be within 330 ft (100 m) of each other. 
• To maximize wireless range, place units away from large metallic items, thick  

  walls, metal surfaces, or other objects that may limit wireless communication.
• To prevent wireless interference, place both units at least 3 ft (.9 m) away    

  from electronic devices (TV, computer, microwave, radio, etc.).

Setup is Complete

The sensor will now synchronize with the display unit. It may take a few 

minutes for synchronization to complete. Please refer to the troubleshooting 

section of this manual if anything appears to be functioning improperly.

TV

3

(100 meters)

(330 feet maximum)

(.91 m)

AT

LEAST

APART

Содержание 02038W

Страница 1: ...ion 2 Features Benefits Sensor 2 Features Benefits Display 3 Setup 5 Sensor Setup 5 Display Setup 6 Intelli Time Clock 7 Set the Time Date Units 7 Backlight Settings 7 Placement Guidelines 8 Using the...

Страница 2: ...play unit 2 Outdoor sensor 3 Power adapter 4 Instruction manual PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEI...

Страница 3: ...Pressure will self calibrate over a 14 day Learning Mode Manual Pressure Mode Indicates manually calibrated pressure 8 Moon Phase 9 Barometric Pressure Arrow icon indicates the direction the pressure...

Страница 4: ...up preferences 3 Setup Mode Button for setup preferences 4 Adjust Down Button for setup preferences 5 Battery Compartment 6 Reset Button Full reset to factory defaults 7 Battery Compartment Cover 8 Pl...

Страница 5: ...ies are not recommended The sensor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor fo...

Страница 6: ...n rechargeable batteries DO NOT short circuit the supply terminals Display Unit Setup Set the A B C Switch Locate the A B C switch inside the battery compartment Set the A B C switch to A B or C You m...

Страница 7: ...ng Time ON or OFF CLOCK HOUR CLOCK MINUTE CALENDAR MONTH CALENDAR DATE CALENDAR YEAR TEMPERATURE UNITS F or C PRESSURE UNITS inHg or hPa You will automatically exit SET MODE if no buttons are pressed...

Страница 8: ...a well covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accur...

Страница 9: ...4 hours by collecting data from the sensor in your backyard It generates a forecast with pinpoint accuracy personalized for your exact location OPERATION View the complete list of icons at www AcuRite...

Страница 10: ...r indoor and outdoor temperature and humidity Today s records automatically clear at 12 00am midnight every day To manually clear all of today s LOW recorded values press and hold the button for 2 sec...

Страница 11: ...h other for about 20 minutes to gain a strong connection Inaccurate forecast Weather Forecast icon predicts conditions for the next 12 to 24 hours not current conditions Has Learning Mode icon disappe...

Страница 12: ...ess the or buttons to calibrate the data value higher or lower from the actual reading 4 Press the button to confirm the calibration adjustment The icon will remain illuminated next to calibrated valu...

Страница 13: ...and the power adapter is unplugged To exit manual pressure mode and return to auto mode press and hold the button for at least 10 seconds Replace Intelli Time Battery Remove small screw to gain acces...

Страница 14: ...ned by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separ...

Страница 15: ...es are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liab...

Страница 16: ...ve owners Patent numbers 5 978 738 6 076 044 6 597 990 US 7 637 141 B2 Printed in China 02038 INST 113012 It s more than accurate it s AcuRite offers an extensive assortment of precision instruments d...

Отзывы: