TESTING and MAINTENANCE

TEST 

button

SDRT option: aim 
laser pointer here 

Indication:

Status:

Off

Unit is off

Flashing green

Unit is in Emergency operation or Test

Solid amber

Battery is charging

Solid green

Battery is fully charged

Flashing R / G

Manual test, battery not fully charged 

(SDRT 

only)

1x red flashing

Battery failure 

(SDRT only)

2x red flashing

Lamp assembly failure 

(SDRT only)

3x red flashing

Charger / electronics failure 

(SDRT only)

Flashing R/Amber Unable to charge

Solid Red

Battery is disconnected

Unit Status Indications

The “TEST” button illuminates to indicate the following conditions:

LIFE SAFETY SOLUTIONS

TEL:  800-705-SERV (7378

www.lithonia.com

[email protected]

AFFINITY

®

NOTE: Emergency lighting systems should be tested in
accordance with NFPA 101 or as often as local codes
require, to ascertain that all components are operational.
NOTE: Allow batteries to charge for 24 hours before initial
testing.

Manual testing:

If the batteries are sufficiently charged, either press and release
the

“TEST” button or use the RTKIT (remote tester accessory,

up to 40

’ away for SDRT units only) on the bottom of the unit to

activate a 60-second test, during which the lamps will turn on.
Triggering either option a second time will enable a 90-minute
tests indicated by 5 flashes of the lamps.

Triggering either

option a third time will disable manual testing.

Self-Diagnostics (SDRT feature)

Units with this option automatically perform a 5-minute self-
diagnostic test of the charging electronics, battery, and lamps
every 30 days, and a 90-minute test every year, indicating
system status as shown in the table at right. First self test
occurs after 15 days of continuous AC Power.

Postponing a self-test:

If an automatic self-test occurs at a time when it is not desirable
for the unit lamps to be on, it can be postponed for 8 hours
either by pressing and releasing the

“TEST” button or by using

RTKIT (remote tester accessory, up to 40

’ away).

Cancelling emergency operation:

While in emergency mode, press and hold the

“TEST” button for

several seconds or activate using the RTKIT (remote tester
accessory, up to 40

’ away), during which the status indicator

will flash until the lamps turn off. This restores the AC reset
state in which the unit is shipped.

Load-Learning feature:

Self-Diagnostic units automatically

‘learn’ their total connected

lamp load during the first scheduled self-test (~15 days) or the
first manual test after the battery is fully charged. The learned
value can be reset by pressing and holding the

“TEST” button

for 7 seconds (count flashes), during this period the lamps will
turn on. After 7 seconds, release the button, the lamps will turn
off within 2 seconds indicating learn reset complete. If lamps
stay on longer, learn reset was not successful. This manual
learn reset feature should be performed whenever the total
connected lamp load of the unit is changed, or a lamp is
replaced. A new learned value will be stored during the next
discharge from a fully charged state.

NOTE: Manual load-learning functions cannot be initiated if
there is inadequate charge in the batteries. If this is so, wait
until the unit indicates full battery charge (solid green status
indication) before initiating the manual load-learning function.
NOTE:

The remote tester should not be used to initiate the

Load Learning feature.

Clearing a failure indication:

After a failure condition has been corrected and power is
restored to the unit, clear the failure indication either by
pressing the

“TEST” button once or by using the RTKIT (remote

tester accessory, up to 40

’ away).

Remote

Test

(SDRT

-

Optional):

(RTKIT

sold

separately)

Units with the self-diagnostics/remote test feature allows manual
test activation using a laser pointer. Aim the laser beam straight
onto the circular area labeled near the

“TEST” button for a few

moments to activate a 60-second test. (See also

“Manual testing”)

A test in progress may be cancelled by aiming the beam at the
test area again.

NOTE:

The remote tester should not be used to

initiate the load learning feature.

IMPORTANT BATTERY INFORMATION:

Batteries are perishable items. For best results, it is recommended
that the batteries receive an initial charge within the first six months
of the manufacture date of the fixture. The manufacture date can
be found on the outside of the unit packaging and on the product
label as part of the Date Code / Series. The first two digits in the
date code represent the year and the second two digits represent
the month. In many cases, batteries beyond the initial charge
recommendation time frame will recover if fully charged soon after
installation. If such a battery does not recover after a full initial
charge, it should be replaced.

912-00020-001 

Rev. D, 3/2021

© 2020, Acuity Brand Lighting,Inc. 

All Rights Reserved.

Содержание Lithonia Lighting AFFINITY AFB

Страница 1: ...NING The battery used in this device may present a risk of fire or chemical burn if mistreated Temperature range 32 F 122 F 0 C 50 C with Non CW unit and 22 F 122 F 30 C 50 C for CW units Do not disas...

Страница 2: ...box and prepare the lead ends to make connections to the fixture leads On the rear housing remove the round center knockout 1 2 diameter and the desired pair of keyhole knockouts Use knockouts instead...

Страница 3: ...AFETY SOLUTIONS TEL 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com AFFINITY PREPARING THE UNIT FOR CONDUIT Remove the conduit plug from inside The unit is threaded to accept...

Страница 4: ...Self Diagnostic units automatically learn their total connected lamp load during the first scheduled self test 15 days or the first manual test after the battery is fully charged The learned value can...

Страница 5: ...t pinched LiFepo4 battery Battery Strap NiCad battery Unscrew screws Light engine bracket Re assemble unit 2 Reconnect the new battery to the charger board 3 2 Remove screws from the plastic cover and...

Страница 6: ...erference LIFE SAFETY SOLUTIONS TEL 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com AFFINITY AC Input Line Pin Details Pin 1 White Neutral Pin 3 Black HOT 120 347Vac AC Input...

Страница 7: ...SSEMENT La batterie utilis e pour cet appareil peut tre l origine d incendies ou de br lures chimiques en cas de mauvaise manipulation Plage de temp rature de 0 C 50 C 32 F 122 F avec les unit s sans...

Страница 8: ...it s des fils pour effectuer les connexions aux fils du luminaire Sur le bo tier arri re enlevez le trou central rond 1 2 po de diam tre et la paire de trous de serrure souhait e Utilisez des d bouchu...

Страница 9: ...05 SERV 7378 www lithonia com techsupport emergency acuitybrands com PR PARATION DE L APPAREIL POUR LE CONDUIT Retirer le bouchon du conduit de l int rieur L appareil est filet pour accepter les filet...

Страница 10: ...ionnalit d apprentissage de la charge Les unit s d auto diagnostic retiennent automatiquement la charge totale de la lampe branch e lors du premier essai automatique planifi 15 jours ou lors du premie...

Страница 11: ...ngle de la batterie Batterie Ni Cd D vissez les vis Support du moteur du luminaire R assemblez l appareil 2 Rebranchez la nouvelle batterie la carte du chargeur 3 2 Retirez les vis du couvercle en pla...

Страница 12: ...NS DE S CURIT DES PERSONNES T L 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com D tails des broches de la ligne d entr e CA Broche 1 blanche Neutre Broche 3 noire CHARG E 120...

Страница 13: ...ispositivo puede presentar un riesgo de incendio o de quemadura qu mica si no se utiliza correctamente Rango de temperatura 32 F 122 F 0 C 50 C con unidad sin CW y 22 F 122 F 30 C 50 C para unidades C...

Страница 14: ...vo En la carcasa trasera retire el orificio central redondo 1 2 in de di metro y el par de orificios troquelados deseados Use perforaciones en lugar de perforar agujeros para evitar que las virutas de...

Страница 15: ...PERSONAL TEL FONO 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com AFFINITY PREPARE LA UNIDAD PARA EL CONDUCTO Retire el tap n del conducto desde el interior La unidad est ros...

Страница 16: ...e Las unidades de autodiagn stico aprenden autom ticamente su carga total de la l mpara conectada durante la primera autoevaluaci n programada aproximadamente 15 d as o en la primera prueba manual lue...

Страница 17: ...a Bater a NiCad Desatornillar los tornillos Soporte del motor de la luz Vuelva a montar la unidad 2 Reconecte la bater a nueva a la placa del cargador 3 2 Retire los tornillos de la cubierta de pl sti...

Страница 18: ...a interferencia da ina SOLUCIONES DE SEGURIDAD PERSONAL TEL FONO 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com Detalles de Pin de l nea de entrada de CA Pin 1 blanco Neutro...

Отзывы: