INSTALLATION and WIRING 

1

2

Alignment pin

Sheet metal 
clip

Ensure all wires and connectors are routed 
to avoid interference with other components. 
Line up the alignment pins (located at 
diagonally opposite corners of the front 
housing) with the mating receptacles (two on 
the rear housing). 

To properly close the unit, it is important to push the cover 
straight onto the rear housing. If the pins are not aligned with 
the receptacles, the housing will not close properly. Make sure 
there are no gaps between the front and rear housings.  If gap 
is present, open the unit and reinstall the front housing.

FINAL ASSEMBLY

1

SURFACE CONDUIT MOUNTING

NOTE: to avoid interference with components in the housing, use the most compact wire connectors appropriate to the wire
gauge.

LIFE SAFETY SOLUTIONS

TEL:  800-705-SERV (7378

www.lithonia.com

[email protected]

AFFINITY

®

PREPARING THE UNIT FOR CONDUIT : 

Remove the conduit plug from inside.  The 
unit is threaded to accept 1/2” NPT threads 
(14 TPI), which are common in rigid conduit 
and EMT connector products. Rigid conduit 
or EMT fittings can be directly threaded into 
the housing without the need for a locknut. 
For wet locations, use an approved wet 
location fitting.

2

BRANCH CIRCUIT WIRING :

The wiring compartment is sized for (3) incoming 12 AWG 
wires and (3) outgoing 12 AWG wires and common wire 
connectors. If your branch circuit is a larger AWG or you have 
a need for a through-wire application, install the branch circuit 
raceway such that you do not have to pass the circuit through 
the fixture.

Conduit plug

Open 

(Clockwise) *

Sized for ½” conduit

* A right-angle screwdriver may be required to break 
the plug from the paint 

912-00020-001 

Rev. D, 3/2021

© 2020, Acuity Brand Lighting,Inc. 

All Rights Reserved.

Содержание Lithonia Lighting AFFINITY AFB

Страница 1: ...NING The battery used in this device may present a risk of fire or chemical burn if mistreated Temperature range 32 F 122 F 0 C 50 C with Non CW unit and 22 F 122 F 30 C 50 C for CW units Do not disas...

Страница 2: ...box and prepare the lead ends to make connections to the fixture leads On the rear housing remove the round center knockout 1 2 diameter and the desired pair of keyhole knockouts Use knockouts instead...

Страница 3: ...AFETY SOLUTIONS TEL 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com AFFINITY PREPARING THE UNIT FOR CONDUIT Remove the conduit plug from inside The unit is threaded to accept...

Страница 4: ...Self Diagnostic units automatically learn their total connected lamp load during the first scheduled self test 15 days or the first manual test after the battery is fully charged The learned value can...

Страница 5: ...t pinched LiFepo4 battery Battery Strap NiCad battery Unscrew screws Light engine bracket Re assemble unit 2 Reconnect the new battery to the charger board 3 2 Remove screws from the plastic cover and...

Страница 6: ...erference LIFE SAFETY SOLUTIONS TEL 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com AFFINITY AC Input Line Pin Details Pin 1 White Neutral Pin 3 Black HOT 120 347Vac AC Input...

Страница 7: ...SSEMENT La batterie utilis e pour cet appareil peut tre l origine d incendies ou de br lures chimiques en cas de mauvaise manipulation Plage de temp rature de 0 C 50 C 32 F 122 F avec les unit s sans...

Страница 8: ...it s des fils pour effectuer les connexions aux fils du luminaire Sur le bo tier arri re enlevez le trou central rond 1 2 po de diam tre et la paire de trous de serrure souhait e Utilisez des d bouchu...

Страница 9: ...05 SERV 7378 www lithonia com techsupport emergency acuitybrands com PR PARATION DE L APPAREIL POUR LE CONDUIT Retirer le bouchon du conduit de l int rieur L appareil est filet pour accepter les filet...

Страница 10: ...ionnalit d apprentissage de la charge Les unit s d auto diagnostic retiennent automatiquement la charge totale de la lampe branch e lors du premier essai automatique planifi 15 jours ou lors du premie...

Страница 11: ...ngle de la batterie Batterie Ni Cd D vissez les vis Support du moteur du luminaire R assemblez l appareil 2 Rebranchez la nouvelle batterie la carte du chargeur 3 2 Retirez les vis du couvercle en pla...

Страница 12: ...NS DE S CURIT DES PERSONNES T L 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com D tails des broches de la ligne d entr e CA Broche 1 blanche Neutre Broche 3 noire CHARG E 120...

Страница 13: ...ispositivo puede presentar un riesgo de incendio o de quemadura qu mica si no se utiliza correctamente Rango de temperatura 32 F 122 F 0 C 50 C con unidad sin CW y 22 F 122 F 30 C 50 C para unidades C...

Страница 14: ...vo En la carcasa trasera retire el orificio central redondo 1 2 in de di metro y el par de orificios troquelados deseados Use perforaciones en lugar de perforar agujeros para evitar que las virutas de...

Страница 15: ...PERSONAL TEL FONO 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com AFFINITY PREPARE LA UNIDAD PARA EL CONDUCTO Retire el tap n del conducto desde el interior La unidad est ros...

Страница 16: ...e Las unidades de autodiagn stico aprenden autom ticamente su carga total de la l mpara conectada durante la primera autoevaluaci n programada aproximadamente 15 d as o en la primera prueba manual lue...

Страница 17: ...a Bater a NiCad Desatornillar los tornillos Soporte del motor de la luz Vuelva a montar la unidad 2 Reconecte la bater a nueva a la placa del cargador 3 2 Retire los tornillos de la cubierta de pl sti...

Страница 18: ...a interferencia da ina SOLUCIONES DE SEGURIDAD PERSONAL TEL FONO 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com Detalles de Pin de l nea de entrada de CA Pin 1 blanco Neutro...

Отзывы: