Acuity Brands Lithonia Lighting AFFINITY AFB Скачать руководство пользователя страница 1

AFB

EMERGENCY LIGHTING UNIT

Installation and wiring.

…………………………………………….…………………...……………...… Page 2-3

Testing and maintenance .

……………..…………......………………………………………………… Page 4

Maintenance

………...……………………..…………………………………………………………...…Page 5-6

Wiring diagram

….…...……………………..………………………………………………………..…….Page 6

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions 

should always be followed, including the following:

!

!

!

!

!

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

WARNING:

FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, SERIOUS INJURY OR

SIGNIFICANT PROPERTY DAMAGE

- For your protection, read and follow these warnings and instructions carefully before installing or

maintaining this equipment. These instructions do not attempt to cover all installation and maintenance situations. If you do not understand these

instructions or additional information is required, contact Lithonia Lighting or your local Lithonia Lighting distributor.

WARNING:

RISK OF ELECTRIC SHOCK

NEVER CONNECT TO, DISCONNECT FROM OR SERVICE WHILE EQUIPMENT IS

ENERGIZED

.

WARNING:

DO NOT USE ABRASIVE MATERIALS OR SOLVENTS. USE OF THESE SUBSTANCES MAY DAMAGE FIXTURE, WHICH

MAY RESULT IN PERSONAL INJURY

.

WARNING:

RISK OF PERSONAL INJURY

This product may have sharp edges. Wear gloves to prevent cuts or abrasions when removing

from carton, handling, installing and maintaining this product.

WARNING:

The battery used in this device may present a risk of fire or chemical burn if mistreated. Temperature range 32

°

F -122

°

F (0

°

C - 50

°

C)

with Non-CW unit and -22

°

F -122

°

F (-30

°

C - 50

°

C) for CW units. Do not disassemble or heat above 70

°

C (158

°

F) or incinerate. Battery should not be

used in an application where the temperature is lower than what is rated on the spec sheet. Replace battery only as directed on the battery label and

page 4 of these instructions. Use of unauthorized battery voids warranty and UL listing of this product and may present a risk of fire or explosion.

WARNING:

For switched line applications only the PEL unit(s) shall be connected. No other switched products shall be connected on the switched

leg.

•Disconnect A.C. power before servicing.

•All servicing should be performed by qualified personnel.

•Consult your local building code for approved wiring and installation.

•For use Outdoors. Failure to ensure conduit connections are properly protected against water ingress during installation may void warranty

.

•Do not mount near gas or electric heater.

•Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.

•The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

•Do not use this equipment for other than intended use.

SAVE THESE INSTRUCTIONS

AND DELIVER TO OWNER AFTER INSTALLATION

AFFINITY

®

!

Содержание Lithonia Lighting AFFINITY AFB

Страница 1: ...NING The battery used in this device may present a risk of fire or chemical burn if mistreated Temperature range 32 F 122 F 0 C 50 C with Non CW unit and 22 F 122 F 30 C 50 C for CW units Do not disas...

Страница 2: ...box and prepare the lead ends to make connections to the fixture leads On the rear housing remove the round center knockout 1 2 diameter and the desired pair of keyhole knockouts Use knockouts instead...

Страница 3: ...AFETY SOLUTIONS TEL 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com AFFINITY PREPARING THE UNIT FOR CONDUIT Remove the conduit plug from inside The unit is threaded to accept...

Страница 4: ...Self Diagnostic units automatically learn their total connected lamp load during the first scheduled self test 15 days or the first manual test after the battery is fully charged The learned value can...

Страница 5: ...t pinched LiFepo4 battery Battery Strap NiCad battery Unscrew screws Light engine bracket Re assemble unit 2 Reconnect the new battery to the charger board 3 2 Remove screws from the plastic cover and...

Страница 6: ...erference LIFE SAFETY SOLUTIONS TEL 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com AFFINITY AC Input Line Pin Details Pin 1 White Neutral Pin 3 Black HOT 120 347Vac AC Input...

Страница 7: ...SSEMENT La batterie utilis e pour cet appareil peut tre l origine d incendies ou de br lures chimiques en cas de mauvaise manipulation Plage de temp rature de 0 C 50 C 32 F 122 F avec les unit s sans...

Страница 8: ...it s des fils pour effectuer les connexions aux fils du luminaire Sur le bo tier arri re enlevez le trou central rond 1 2 po de diam tre et la paire de trous de serrure souhait e Utilisez des d bouchu...

Страница 9: ...05 SERV 7378 www lithonia com techsupport emergency acuitybrands com PR PARATION DE L APPAREIL POUR LE CONDUIT Retirer le bouchon du conduit de l int rieur L appareil est filet pour accepter les filet...

Страница 10: ...ionnalit d apprentissage de la charge Les unit s d auto diagnostic retiennent automatiquement la charge totale de la lampe branch e lors du premier essai automatique planifi 15 jours ou lors du premie...

Страница 11: ...ngle de la batterie Batterie Ni Cd D vissez les vis Support du moteur du luminaire R assemblez l appareil 2 Rebranchez la nouvelle batterie la carte du chargeur 3 2 Retirez les vis du couvercle en pla...

Страница 12: ...NS DE S CURIT DES PERSONNES T L 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com D tails des broches de la ligne d entr e CA Broche 1 blanche Neutre Broche 3 noire CHARG E 120...

Страница 13: ...ispositivo puede presentar un riesgo de incendio o de quemadura qu mica si no se utiliza correctamente Rango de temperatura 32 F 122 F 0 C 50 C con unidad sin CW y 22 F 122 F 30 C 50 C para unidades C...

Страница 14: ...vo En la carcasa trasera retire el orificio central redondo 1 2 in de di metro y el par de orificios troquelados deseados Use perforaciones en lugar de perforar agujeros para evitar que las virutas de...

Страница 15: ...PERSONAL TEL FONO 800 705 SERV 7378 www lithonia com techsupport emergency acuitybrands com AFFINITY PREPARE LA UNIDAD PARA EL CONDUCTO Retire el tap n del conducto desde el interior La unidad est ros...

Страница 16: ...e Las unidades de autodiagn stico aprenden autom ticamente su carga total de la l mpara conectada durante la primera autoevaluaci n programada aproximadamente 15 d as o en la primera prueba manual lue...

Страница 17: ...a Bater a NiCad Desatornillar los tornillos Soporte del motor de la luz Vuelva a montar la unidad 2 Reconecte la bater a nueva a la placa del cargador 3 2 Retire los tornillos de la cubierta de pl sti...