background image

2.2.7

  Locate the free end of the second cable.  Without

wrapping or crossing the cables, especially with the
cable already installed, thread this cable through its
respective opening in the cable divider plate, over the
pulleys and through the latch barrel.  Continue to pull
the cable to remove the slack.  String the last hoisting
cable in the same manner.  Check to see that the
positions of the cable attachments to the clevis are
aligned with the openings in the cable divider plate.

CAUTION

Be sure the cables are not crossed or wrapped around
each other.  Fouled cables may cause cable damage
and improper device operation.

2.2.8

  Thread the power cord through the power cord

slot, near the outside edge of head frame plate, over
the power cord rollers and through the slot of the cable
divider plate adjacent to the cord roller.  (See Figure 4)

2.2.9

  Feed the power cord through the large center

hole in the clevis approximately 2 feet, making certain it
is centered in the three hoisting cables.

CAUTION

The power cord and cables must not be crossed or
wrapped around each other.

2.2.10

  Securely fasten the compression clamp on the

power cable just under the clevis plate.  The location of
the clamp is not critical at this time.  The clamp will be
repositioned after the pole is erected.

NOTE

Double-check for crossed or wrapped cables and cord
at this time.  With the clevis located near the slipfitter it
is very simple to check for proper assembly.  After the
pole is erected, it will be nearly impossible.

2.2.11

  Attach the light rope, wire or cable, which was

strung through the pole, to the U-shaped bail of the
clevis and pull the clevis into the top of the pole. (See
Figure 5)

HOLOPHANE

High Mast
Lowering Devices

SECTION II

2.2.12

  Pick up the headframe assembly and slide the

slipfitter over the top of the pole while pulling the clevis
down the pole to take up slack in the cables. (See
Figure 6)  After orienting the headframe with the power
cord on the top, aligned with the pole handhole tighten
the six set screws to 25 to 30 inch pounds .

2.2.13

  Pull all cables down through the pole and stop

when the clevis is at the top of the upper handhole.

2.3  Installing the Circuit Breaker and Stringer Hook

2.3.1

  Unpack the circuit breaker plate assembly with

the attached cover. (See Figure 7)

2.3.2

  Remove the circuit breaker cover. The circuit

breaker cord remains attached.

Figure 5

Figure 4

Figure 3

CLEVIS

COMPRESSION
CLAMP

GR1132

GR1133

GR1134

6

Содержание Holophane 15

Страница 1: ...ity Brands Lighting Inc assumes no responsibility for claims arising out of improper or careless installation or handling of its products 2010 Acuity Brands Lighting Inc All rights reserved 6 03 13 AB...

Страница 2: ...hane Refer to the manual number in the lower right corner of this page Less detailed information regarding installation operation and main tenance of Holophane Lowering Devices is available in VHS vid...

Страница 3: ...ting and maintenance personnel must read and understand completely Sections III and IV 3 Additional copies of this manual are available from Holophane 4 To expedite information and service call 740 34...

Страница 4: ...ons Section III Operating Instructions Section IV Maintenance Instructions 4 1 LUBRICATION 4 2 REPLACING THE WINCH CABLE 4 3 PORTABLE DRIVE MOTOR SHAFT REPLACEMENT 4 4 POWER CORD REPLACEMENT 4 5 LUMIN...

Страница 5: ...junction box one per Clevis assembly with coiled hoisting cables one per Circuit breaker assembly and enclosure one per Luminaire mounting arms quantity as required Safety cable and stringing hook one...

Страница 6: ...GR1129 4...

Страница 7: ...2 2 3 Unpack the junction box with the main power cord and place near the top of pole Uncoil the power cord halfway down along the pole and back to the top Uncoil in a manner that will not leave the...

Страница 8: ...on the power cable just under the clevis plate The location of the clamp is not critical at this time The clamp will be repositioned after the pole is erected NOTE Double check for crossed or wrapped...

Страница 9: ...side the pole Make sure the clevis pin is secured with a cotter pin See Figure 8 The stringing hook keeps the clevis from being pulled back up the pole while rigging the hoisting cables and holds the...

Страница 10: ...forced out and may be discarded 2 4 7 Repeat the steps in paragraphs 2 4 4 through 2 4 6 5 for the remaining two cables CAUTION Make sure all the hoisting cables are seated in their respective pulley...

Страница 11: ...the ring at the location immediately adjacent and to the right of the power cord slot See Figure 14 2 5 4 Install the junction box onto the left side of the junction box arm using the four 1 4 20 nuts...

Страница 12: ...luminaires mount the FAA marker at any vacant luminaire mounting position Counterweight locations Mount counterweight at these locations for lowering devices with 2 3 and 4 luminaires IMPORTANT The co...

Страница 13: ...g near the power cord strain plate The rope length must be at least the length of the pole This will be used to apply downward force on the ring in the event that the size and length of the power cord...

Страница 14: ...Do not unhook the stringing hook until the power unit is firmly installed in the pole Do not leave this too long since it can become entangled with the winch cable Reference the wiring diagram insert...

Страница 15: ...The device complete with luminaires 2 7 4 The portable drive motor can now be used to pull itself into the lower handhole Rotate the switch to the FOR position The tongue of the power unit will be pul...

Страница 16: ...uit breaker cord from the portable drive motor or transformer and connect it to the main power cord in the pole 2 8 12 Remove the portable drive motor place the manual in the plastic pouch provided an...

Страница 17: ...SINGLE CIRCUIT WIRING DIAGRAMS GR1164 GR1165 GR1166 15...

Страница 18: ...DOUBLE CIRCUIT WIRING DIAGRAMS GR1167 GR1168 16...

Страница 19: ...BEFORE OPERATING THE DEVICE 3 0 General Comments 3 0 1 The portable drive motor is provided with a twenty foot long remote control cord and switch This permits the operator to stand a safe distance f...

Страница 20: ...not break and make the circuit with the plug and connector Use the circuit breaker Failure to use the circuit breaker may result in electrical shock 3 3 1 Turn off the circuit breaker 3 3 2 Disconnect...

Страница 21: ...release to OFF as soon as the latch flags rotate perpendicular to the ring See Figure 27 3 4 4 Unwind the winch just enough to remove tension from the winch cable 3 5 Final Steps 3 5 1 Loosen the han...

Страница 22: ...then discard the cable 4 2 3 Attach the new cable obtained from Holophane in the same manner that the old cable was attached 4 2 4 While rewinding the winch wrap as tightly and neatly as possible to a...

Страница 23: ...ring approxi mately 10 ft while keeping tension on the old cord Then lower the ring and the cord will come down with it HOLOPHANE High Mast Lowering Devices SECTION IV 4 4 13 Disconnect the old cord...

Страница 24: ...HOLOPHANE High Mast Lowering Devices SECTION V ATTACHMENTS 22...

Страница 25: ...IM 187 E 1 13 2013 Acuity Brands Inc Visit our web site at www holophane com Acuity Lighting Group Inc Field Service Department P O Box3004 Newark OH43058 3004 Printed in USA...

Отзывы: