background image

4.4  POWER CORD REPLACEMENT

4.4.1

  Remove the handhole cover.  Turn the circuit

breaker off.  Disconnect the plug and connector.

4.4.2

  Remove power cord plug and the cord clamp that

is positioned just under the clevis.

4.4.3

  Strip 18 in. of the outer jacket off the end of the

power cord.  Be sure the power cord stays in the center
of the clevis assembly.

4.4.4

  Strip 18 in. of the outer jacket off the end of the

new replacement cord.  If either or both power cords
have more than three conductors, cut the extras off as
they are not needed.

4.4.5

  Braid the two cords together end-to-end (approx.

18”).  Keep the braid tight and the diameter as small as
possible.

4.4.6

  Attach small gauge wire ties approximately 2

inches apart the whole length of the braid.

4.4.7

  Cut off the excess conductor ends used in

braiding and wrap the complete connection with tape.
Check to see that the splice will pass freely through the
hole in the clevis. If not, rework the splice until it will.

4.4.8

  Install the cord grip, rubber boot (if used) and

plug to the other end of the replacement cord.  (See
Figure 20).

4.4.9

  Connect the circuit breaker cord to the portable

drive motor or to the transformer as required.  Turn on
the circuit breaker.  Unlatch and lower the ring.  Be sure
the new power cord feeds properly into handhole as the
ring is lowered.

4.4.10

  Tie a light rope to the new power cord near the

plug.

4.4.11

  Pull on the old power cord, pulling the new cord

over the pulleys and down the outside of the pole.  As
the power cord is pulled, keep tension on the rope
since the cord will begin to move due to its own weight.

4.4.12

  The new power cord may not come all the way

down to the ring.  If this happens, raise the ring approxi-
mately 10 ft. while keeping tension on the old cord.
Then lower the ring and the cord will come down with it.

H O L O P H A N E

High Mast
Lowering Devices

SECTION IV

4.4.13

  Disconnect the old cord from the cord clamp and

junction box on the ring and cut the new cord just above
the splice and thread it down through the cord clamp and
into the junction box.

CAUTION

Limit the length of cord between the junction box and
the cord clamp to avoid its interference with the iris arm
mechanisms.

Remove the slack in the cord.  Tighten all the cord
clamps and wire the new cord into the terminal blocks.
Check the circuit.

4.4.14

  Raise and latch the device.

4.4.15

  Check the cord grip at the clevis and make sure

the spacing is correct.  (See Figure 20)

4.4.16

  Turn off the circuit breaker.

4.4.17

  Disconnect the pigtail connector from the power

unit and connect it to the lighting power cord.

4.4.18

  Turn on the circuit breaker.

4.5  LUMINAIRE REMOVAL

CAUTION

If it is necessary to remove a luminaire or components
of a luminaire that is mounted on the ring assembly,
make sure the luminaire or its components, or an
equivalent weight, is returned to its mounting arm
before attempting to latch the device.  Failure to do this
may result in the device not latching or unlatching
properly.

4.6  LATCH SYNCHRONIZATION ADJUSTMENT
AND LATCHING

CAUTION

This adjustment is necessary to insure that the device
will latch and unlatch dependably.

4.6.1

  The adjustment of the hoisting cables is accom-

plished by using wooden cable markers attached to the
hoisting cables.  These markers are positioned by
raising the mounting ring until markers slide down the
cables as they are against the latch barrels.  The ring is
lowered, measurements are taken, and cable adjust-
ments made.  For complete step by step instructions to
accomplish this, refer to paragraphs 2.8.1 through
2.8.7.  Carefully follow all steps.

21

Содержание Holophane 15

Страница 1: ...ity Brands Lighting Inc assumes no responsibility for claims arising out of improper or careless installation or handling of its products 2010 Acuity Brands Lighting Inc All rights reserved 6 03 13 AB...

Страница 2: ...hane Refer to the manual number in the lower right corner of this page Less detailed information regarding installation operation and main tenance of Holophane Lowering Devices is available in VHS vid...

Страница 3: ...ting and maintenance personnel must read and understand completely Sections III and IV 3 Additional copies of this manual are available from Holophane 4 To expedite information and service call 740 34...

Страница 4: ...ons Section III Operating Instructions Section IV Maintenance Instructions 4 1 LUBRICATION 4 2 REPLACING THE WINCH CABLE 4 3 PORTABLE DRIVE MOTOR SHAFT REPLACEMENT 4 4 POWER CORD REPLACEMENT 4 5 LUMIN...

Страница 5: ...junction box one per Clevis assembly with coiled hoisting cables one per Circuit breaker assembly and enclosure one per Luminaire mounting arms quantity as required Safety cable and stringing hook one...

Страница 6: ...GR1129 4...

Страница 7: ...2 2 3 Unpack the junction box with the main power cord and place near the top of pole Uncoil the power cord halfway down along the pole and back to the top Uncoil in a manner that will not leave the...

Страница 8: ...on the power cable just under the clevis plate The location of the clamp is not critical at this time The clamp will be repositioned after the pole is erected NOTE Double check for crossed or wrapped...

Страница 9: ...side the pole Make sure the clevis pin is secured with a cotter pin See Figure 8 The stringing hook keeps the clevis from being pulled back up the pole while rigging the hoisting cables and holds the...

Страница 10: ...forced out and may be discarded 2 4 7 Repeat the steps in paragraphs 2 4 4 through 2 4 6 5 for the remaining two cables CAUTION Make sure all the hoisting cables are seated in their respective pulley...

Страница 11: ...the ring at the location immediately adjacent and to the right of the power cord slot See Figure 14 2 5 4 Install the junction box onto the left side of the junction box arm using the four 1 4 20 nuts...

Страница 12: ...luminaires mount the FAA marker at any vacant luminaire mounting position Counterweight locations Mount counterweight at these locations for lowering devices with 2 3 and 4 luminaires IMPORTANT The co...

Страница 13: ...g near the power cord strain plate The rope length must be at least the length of the pole This will be used to apply downward force on the ring in the event that the size and length of the power cord...

Страница 14: ...Do not unhook the stringing hook until the power unit is firmly installed in the pole Do not leave this too long since it can become entangled with the winch cable Reference the wiring diagram insert...

Страница 15: ...The device complete with luminaires 2 7 4 The portable drive motor can now be used to pull itself into the lower handhole Rotate the switch to the FOR position The tongue of the power unit will be pul...

Страница 16: ...uit breaker cord from the portable drive motor or transformer and connect it to the main power cord in the pole 2 8 12 Remove the portable drive motor place the manual in the plastic pouch provided an...

Страница 17: ...SINGLE CIRCUIT WIRING DIAGRAMS GR1164 GR1165 GR1166 15...

Страница 18: ...DOUBLE CIRCUIT WIRING DIAGRAMS GR1167 GR1168 16...

Страница 19: ...BEFORE OPERATING THE DEVICE 3 0 General Comments 3 0 1 The portable drive motor is provided with a twenty foot long remote control cord and switch This permits the operator to stand a safe distance f...

Страница 20: ...not break and make the circuit with the plug and connector Use the circuit breaker Failure to use the circuit breaker may result in electrical shock 3 3 1 Turn off the circuit breaker 3 3 2 Disconnect...

Страница 21: ...release to OFF as soon as the latch flags rotate perpendicular to the ring See Figure 27 3 4 4 Unwind the winch just enough to remove tension from the winch cable 3 5 Final Steps 3 5 1 Loosen the han...

Страница 22: ...then discard the cable 4 2 3 Attach the new cable obtained from Holophane in the same manner that the old cable was attached 4 2 4 While rewinding the winch wrap as tightly and neatly as possible to a...

Страница 23: ...ring approxi mately 10 ft while keeping tension on the old cord Then lower the ring and the cord will come down with it HOLOPHANE High Mast Lowering Devices SECTION IV 4 4 13 Disconnect the old cord...

Страница 24: ...HOLOPHANE High Mast Lowering Devices SECTION V ATTACHMENTS 22...

Страница 25: ...IM 187 E 1 13 2013 Acuity Brands Inc Visit our web site at www holophane com Acuity Lighting Group Inc Field Service Department P O Box3004 Newark OH43058 3004 Printed in USA...

Отзывы: