IMPORTANT SAFETY INSTRUCTIONS 

LOWERING DEVICES 

 

 

 
 
 
 
 

 

 
 

 

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other 
hazards please read all warnings and instructions.  

 

Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. 

 

Installation and service of Lowering Devices should be performed by a 

qualified licensed electrician and mechanical technician

.  

 

Maintenance of the Lowering Devices should be performed by person(s) familiar with the Lowering Devices construction and 
operation and any hazards involved.   

 

DO NOT INSTALL DAMAGED PRODUCT!  

This Lowering Device has been properly packed so that no parts should have been 

damaged during transit. Inspect to confirm.  Any part damaged or broken during or after assembly should be replaced.

 

 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet 
in connection with installation, operation, or maintenance.  Should further information be desired or should particular problems 
arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands 
Lighting, Inc.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 

Failure to follow any of these instructions could void product warranties.   

For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com. 

 
Our Brands

   

Indoor/Outdoor 

 

Indoor Lighting 

 

Outdoor Lighting 

 

Controls

 

 

 

Lithonia Lighting 

 

Gotham 

 

 

American Electric Lighting 

DARK TO LIGHT 

 

 

Carandini 

 

 

Mark Architectural Lighting 

Antique Street Lamps 

 

Lighting Control & Design 

 

 

Holophane   

 

Peerless 

 

 

Hydrel 

 

 

ROAM 

 

 

RELOC  

 

 

Renaissance Lighting 

 

Tersen 

 

 

Sensor Switch 

 

 

 

 

 

Winona Lighting 

 

 

 

 

Synergy 

 

Acuity Brands Lighting, Inc.  assumes no responsibility for claims arising out of improper or careless installation or handling of its products. 

 

© 2010 Acuity Brands Lighting, Inc. All rights reserved. 6/03/13     ABL General Warnings, Form No. 503.204 

 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! 

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION 

 

 

Disconnect or turn off power before installation or servicing. 

 

Verify that supply voltage is correct by comparing it with the luminaire label information. 

 

Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local 
code requirements. 

 

All wiring connections should be capped with UL approved recognized wire connectors. 

 
 
 

 

 

WARNING 

RISK OF ELECTRIC SHOCK 

 
 

 
 

 

 

Do not stand directly beneath the pole or lowering device during installation except as instructed to in this manual. 

 

Do not depend on the lowering device cables to tether a slip-fit type pole. Failure to use a tethering cable may result in injury 
or death. 

 

Operate the lowering device only while standing at the maximum distance from the pole allowed by the twenty foot long 
remote control cord. Failure to follow this procedure

 

may result in injury or death.  

 

Wear gloves, safety glasses, hardhats and safety shoes at all times when removing 

Lowering Devices 

from carton, installing, 

servicing or performing maintenance. 

 

Follow pole manufacture installation instruction. 

 

Follow luminaire manufacture installation instruction when attaching to the lowering device.  

 

Do not expose the torque limiter or shear pin to damaging elements or mistreatment such as sand, mud, salt spray or other 
conditions which could render either safety mechanism inoperable. Do not attempt to adjust the torque limiting clutch or 
replace the shear pin. If repairs are necessary, replace damaged

 

equipment with replacement components from Holophane. 

Failure to follow these warnings may result in injury or death. 

 

 

 
 
 

 

 

CAUTION 

RISK OF INJURY 

Содержание Holophane 15

Страница 1: ...ity Brands Lighting Inc assumes no responsibility for claims arising out of improper or careless installation or handling of its products 2010 Acuity Brands Lighting Inc All rights reserved 6 03 13 AB...

Страница 2: ...hane Refer to the manual number in the lower right corner of this page Less detailed information regarding installation operation and main tenance of Holophane Lowering Devices is available in VHS vid...

Страница 3: ...ting and maintenance personnel must read and understand completely Sections III and IV 3 Additional copies of this manual are available from Holophane 4 To expedite information and service call 740 34...

Страница 4: ...ons Section III Operating Instructions Section IV Maintenance Instructions 4 1 LUBRICATION 4 2 REPLACING THE WINCH CABLE 4 3 PORTABLE DRIVE MOTOR SHAFT REPLACEMENT 4 4 POWER CORD REPLACEMENT 4 5 LUMIN...

Страница 5: ...junction box one per Clevis assembly with coiled hoisting cables one per Circuit breaker assembly and enclosure one per Luminaire mounting arms quantity as required Safety cable and stringing hook one...

Страница 6: ...GR1129 4...

Страница 7: ...2 2 3 Unpack the junction box with the main power cord and place near the top of pole Uncoil the power cord halfway down along the pole and back to the top Uncoil in a manner that will not leave the...

Страница 8: ...on the power cable just under the clevis plate The location of the clamp is not critical at this time The clamp will be repositioned after the pole is erected NOTE Double check for crossed or wrapped...

Страница 9: ...side the pole Make sure the clevis pin is secured with a cotter pin See Figure 8 The stringing hook keeps the clevis from being pulled back up the pole while rigging the hoisting cables and holds the...

Страница 10: ...forced out and may be discarded 2 4 7 Repeat the steps in paragraphs 2 4 4 through 2 4 6 5 for the remaining two cables CAUTION Make sure all the hoisting cables are seated in their respective pulley...

Страница 11: ...the ring at the location immediately adjacent and to the right of the power cord slot See Figure 14 2 5 4 Install the junction box onto the left side of the junction box arm using the four 1 4 20 nuts...

Страница 12: ...luminaires mount the FAA marker at any vacant luminaire mounting position Counterweight locations Mount counterweight at these locations for lowering devices with 2 3 and 4 luminaires IMPORTANT The co...

Страница 13: ...g near the power cord strain plate The rope length must be at least the length of the pole This will be used to apply downward force on the ring in the event that the size and length of the power cord...

Страница 14: ...Do not unhook the stringing hook until the power unit is firmly installed in the pole Do not leave this too long since it can become entangled with the winch cable Reference the wiring diagram insert...

Страница 15: ...The device complete with luminaires 2 7 4 The portable drive motor can now be used to pull itself into the lower handhole Rotate the switch to the FOR position The tongue of the power unit will be pul...

Страница 16: ...uit breaker cord from the portable drive motor or transformer and connect it to the main power cord in the pole 2 8 12 Remove the portable drive motor place the manual in the plastic pouch provided an...

Страница 17: ...SINGLE CIRCUIT WIRING DIAGRAMS GR1164 GR1165 GR1166 15...

Страница 18: ...DOUBLE CIRCUIT WIRING DIAGRAMS GR1167 GR1168 16...

Страница 19: ...BEFORE OPERATING THE DEVICE 3 0 General Comments 3 0 1 The portable drive motor is provided with a twenty foot long remote control cord and switch This permits the operator to stand a safe distance f...

Страница 20: ...not break and make the circuit with the plug and connector Use the circuit breaker Failure to use the circuit breaker may result in electrical shock 3 3 1 Turn off the circuit breaker 3 3 2 Disconnect...

Страница 21: ...release to OFF as soon as the latch flags rotate perpendicular to the ring See Figure 27 3 4 4 Unwind the winch just enough to remove tension from the winch cable 3 5 Final Steps 3 5 1 Loosen the han...

Страница 22: ...then discard the cable 4 2 3 Attach the new cable obtained from Holophane in the same manner that the old cable was attached 4 2 4 While rewinding the winch wrap as tightly and neatly as possible to a...

Страница 23: ...ring approxi mately 10 ft while keeping tension on the old cord Then lower the ring and the cord will come down with it HOLOPHANE High Mast Lowering Devices SECTION IV 4 4 13 Disconnect the old cord...

Страница 24: ...HOLOPHANE High Mast Lowering Devices SECTION V ATTACHMENTS 22...