03.  Unit Features

Auto-Restart After Power 
Failure

If the unit loses power, it will automatically restart with prior settings, once power has been 
restored.

Multiple Wall Controller 
Operation (Optional) 

Up to three wall controllers can be installed on one system. This is particularly useful for larger 
houses, where you can have controls in different locations or if multiple sensing points are 
required.

Room Temp Display with 
One Touch

Simply press 

SELECT UP

 or

 DOWN

 button and the set temperature display will change to show the 

room temperature for 3 seconds.
Note: When zone sensors are fitted, the temperature displayed will depend on which sensor has 
been selected by the wall controller (only applicable to LR7 and LC7-2).

Sense More Technology

Sense More technology means ActronAir systems come with more temperature sensing points, 
which allows them to evenly maintain the temperature throughout your home no matter the time 
of day.

Auto Defrost Function 
(HEATING Mode)

At certain outdoor conditions (low temperature) frost may build up on the outdoor heat 
exchanger. This gradual build up of frost reduces the performance of the air conditioner. The 
microprocessor detects this frost build up and will automatically activate the 

DEFROST

 mode.

The 

DEFROST

 mode is displayed on the wall controller by flashing the 

HEAT

 symbol every 10 

seconds.

Hot Start Function 
(HEATING Mode)

When the air conditioner starts in 

HEATING

 mode, the indoor fan is delayed for a short period 

of time, this allows the heat exchanger to warm up before the air starts to flow, thus preventing 
excessive cold drafts. The hot start feature also activates itself when the system finishes a defrost 
cycle. 

Filter Clean Light

The microprocessor monitors the accumulated run time of the air conditioner and after a preset 
number of hours has passed, the

 FILTER

 light will flash, indicating it is time to check if the filter 

needs cleaning. 
Note: Only applicable to ActronAir wall controllers.

Self Diagnosis

In the unlikely event that a fault develops with the air conditioner the microprocessor will diagnose 
the fault (where possible) and display a fault code on the wall controller.

 NOTE

Refer to individual wall controller owner's manuals for a full list of features.

WALL

CONTROL ONE

WALL

CONTROL TWO

WALL

CONTROLLER ONE

WALL

CONTROLLER TWO

Содержание ADVANCE EAA13AS

Страница 1: ...S EVV15AS CRV17AS EVV17AS CRV13AT EVV13AS CRV15AT EVV15AS CRV17AT EVV17AS IMPORTANT NOTE Please read this manual carefully before operating your air conditioning unit That s better That s Actron Two Piece Fan Coil EAA13AS and EFV13AS EAA15AS and EFV15AS EAA17AS and EFV17AS ...

Страница 2: ...perating Tips for Summer 5 04 02 Operating Tips for Winter 5 04 03 Energy Conservation Tips 5 05 Care and Maintenance 6 06 Maintenance Frequency Checklist 8 07 Troubleshooting 10 WARNING KEEP OUT OF REACH OF CHILDREN Contains button or coin cell battery Hazardous if swallowed Swallowing can lead to chemical burns perforation of soft tissue and death Severe burns can occur within 2 hours of ingesti...

Страница 3: ...ate Electrical Refrigeration and Refrigerant Handling License and Training dependent on local State Territory regulations DANGER Hazardous Voltage Risk of Electrocution Turn Off the power from main isolator before proceeding with any service and maintenance work of the unit Observe proper LOCK OUT TAG OUT LOTO procedures for electrical appliances in order to prevent accidental switching on of the ...

Страница 4: ... low temperature frost may build up on the outdoor heat exchanger This gradual build up of frost reduces the performance of the air conditioner The microprocessor detects this frost build up and will automatically activate the DEFROST mode The DEFROST mode is displayed on the wall controller by flashing the HEAT symbol every 10 seconds Hot Start Function HEATING Mode When the air conditioner start...

Страница 5: ...u raise the temperature set point back to your usual setting OR Start the air conditioner a couple of hours earlier than you normally would in the morning If outside conditions are very cold approximately 7o C or lower supplementary heating may be used such as electric or gas heaters to complement and speed the heating up This can be done by setting an ON timer prior to going to bed Keep all curta...

Страница 6: ...install the filter NOTE When the filter light is flashing check the air filter and clean if necessary and press the ON OFF button to extinguish filter light Always check with your installer for the proper care and maintenance of the filter system Do not obstruct airflow Keep grass or plants away from the unit This will ensure that your air conditioner operates efficiently It is recommended to have...

Страница 7: ...l Connections It may be necessary to work with live electrical components on certain maintenance tasks Only licensed electricians and qualified technicians are allowed to perform these tasks CAUTION Beware of Rotating Fan Blades Always make sure that all power supply to the Outdoor Fans are turn Off and isolated Observe WH S safety procedures do not wear loose clothing and any jewellery when worki...

Страница 8: ...accumulation For highly corrosive environment wash panels quarterly with water and neutral detergent solution Wax panels Repair re paint where required Insulation Visual check for insulation conditions Repair replace insulation material Fan Visual check for run out of balance and dust attached Clean off dust as necessary to negate possibility of fan running out of balance Motor Ω Visual check on w...

Страница 9: ...eat Exchanger Check for clogging by dust Check for leaks damage Clean air inlet side as necessary Straighten any bent fins using fins comb Condensate Drain Line if available Check for obstructions and free flow of water Clean to eliminate obstructions sludge and check condition of drain line Pour water to ensure free flow Compressor Ω Check for high low pressure Measure insulation resistance Check...

Страница 10: ...unit may be louder than normal for a few seconds whilst the compressor reaches the designated speed and operation pressures The outdoor unit makes noises The unit will make different sounds based on its current operating mode Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This c...

Страница 11: ...has been activated Wait 5 minutes after restarting the unit Timer is activated Turn timer off The unit starts and stops frequently There is too much or too little refrigerant in the system Contact a qualified service technician The voltage is too high or too low Contact a qualified service technician Poor heating performance The outdoor temperature is too low Operate system at a lower set temperat...

Страница 12: ...ed Trade Marks of Actron Engineering Pty Limited ActronAir is constantly seeking ways to improve the design of its products Therefore specifications are subject to change without notice Document 9590 8000 Ver 2 Issue Date 06 2022 Refrigerant Trading Authorisation No AU06394 ...

Отзывы: