Please check the following points before contacting a qualified service technician.

Fault

Possible Causes

Remedies

Poor cooling performance

Temperature setting may be higher than 

ambient room temperature.

Lower the temperature setting.

The heat exchanger on the indoor or 

outdoor unit is dirty.

Contact a qualified service technician.

The air filter is dirty.

Remove the filter and clean it according to 

instructions.

The air inlet or outlet of either unit is 

blocked.

Turn the unit off, remove the obstruction and turn 

it back on.

Doors and windows are open.

Make sure that all doors and windows are closed 

while operating the unit.

Excessive heat is generated by sunlight.

Close windows and curtains during periods of high 

heat or bright sunshine.

Too many sources of heat in the room 

(people, computers, electronics, etc.).

Reduce amount of heat sources.

Low refrigerant due to leak or long-term use.

Contact a qualified service technician.

The unit is not working

Power failure.

Wait for the power to be restored.

The power is turned off.

Turn on the power.

The unit's 5 minute protection has been 

activated.

Wait 5 minutes after restarting the unit.

Timer is activated.

Turn timer off.

The unit starts and stops 
frequently

There is too much or too little refrigerant in 

the system.

Contact a qualified service technician.

The voltage is too high or too low.

Contact a qualified service technician.

Poor heating 
performance

The outdoor temperature is too low.

Operate system at a lower set temperature, then 

gradually increase set temp to desired level.

Cold air is entering through doors and 

windows.

Make sure that all doors and windows are closed 

during use.

Low refrigerant due to leak or long-term use.

Contact a qualified service technician.

Indicator lamps continue 
flashing

The unit may stop operation or continue to run safely. Some error codes will allow the unit to 

continue operating. If the indicator lamps continue to flash or error codes appear, wait for about 

10 minutes. The problem may resolve itself. 

If not, disconnect the power, then connect it again. Turn the unit on.

If the problem persists, disconnect the power and contact a qualified service technician. 

Error code appears on the 
controller:
E(xx)

 NOTE

 If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact 
ActronAir on 1800 119 229 for technical support or warranty. Please have the Model and Serial number of  your outdoor unit 
readily available.

Содержание ADVANCE EAA13AS

Страница 1: ...S EVV15AS CRV17AS EVV17AS CRV13AT EVV13AS CRV15AT EVV15AS CRV17AT EVV17AS IMPORTANT NOTE Please read this manual carefully before operating your air conditioning unit That s better That s Actron Two Piece Fan Coil EAA13AS and EFV13AS EAA15AS and EFV15AS EAA17AS and EFV17AS ...

Страница 2: ...perating Tips for Summer 5 04 02 Operating Tips for Winter 5 04 03 Energy Conservation Tips 5 05 Care and Maintenance 6 06 Maintenance Frequency Checklist 8 07 Troubleshooting 10 WARNING KEEP OUT OF REACH OF CHILDREN Contains button or coin cell battery Hazardous if swallowed Swallowing can lead to chemical burns perforation of soft tissue and death Severe burns can occur within 2 hours of ingesti...

Страница 3: ...ate Electrical Refrigeration and Refrigerant Handling License and Training dependent on local State Territory regulations DANGER Hazardous Voltage Risk of Electrocution Turn Off the power from main isolator before proceeding with any service and maintenance work of the unit Observe proper LOCK OUT TAG OUT LOTO procedures for electrical appliances in order to prevent accidental switching on of the ...

Страница 4: ... low temperature frost may build up on the outdoor heat exchanger This gradual build up of frost reduces the performance of the air conditioner The microprocessor detects this frost build up and will automatically activate the DEFROST mode The DEFROST mode is displayed on the wall controller by flashing the HEAT symbol every 10 seconds Hot Start Function HEATING Mode When the air conditioner start...

Страница 5: ...u raise the temperature set point back to your usual setting OR Start the air conditioner a couple of hours earlier than you normally would in the morning If outside conditions are very cold approximately 7o C or lower supplementary heating may be used such as electric or gas heaters to complement and speed the heating up This can be done by setting an ON timer prior to going to bed Keep all curta...

Страница 6: ...install the filter NOTE When the filter light is flashing check the air filter and clean if necessary and press the ON OFF button to extinguish filter light Always check with your installer for the proper care and maintenance of the filter system Do not obstruct airflow Keep grass or plants away from the unit This will ensure that your air conditioner operates efficiently It is recommended to have...

Страница 7: ...l Connections It may be necessary to work with live electrical components on certain maintenance tasks Only licensed electricians and qualified technicians are allowed to perform these tasks CAUTION Beware of Rotating Fan Blades Always make sure that all power supply to the Outdoor Fans are turn Off and isolated Observe WH S safety procedures do not wear loose clothing and any jewellery when worki...

Страница 8: ...accumulation For highly corrosive environment wash panels quarterly with water and neutral detergent solution Wax panels Repair re paint where required Insulation Visual check for insulation conditions Repair replace insulation material Fan Visual check for run out of balance and dust attached Clean off dust as necessary to negate possibility of fan running out of balance Motor Ω Visual check on w...

Страница 9: ...eat Exchanger Check for clogging by dust Check for leaks damage Clean air inlet side as necessary Straighten any bent fins using fins comb Condensate Drain Line if available Check for obstructions and free flow of water Clean to eliminate obstructions sludge and check condition of drain line Pour water to ensure free flow Compressor Ω Check for high low pressure Measure insulation resistance Check...

Страница 10: ...unit may be louder than normal for a few seconds whilst the compressor reaches the designated speed and operation pressures The outdoor unit makes noises The unit will make different sounds based on its current operating mode Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This c...

Страница 11: ...has been activated Wait 5 minutes after restarting the unit Timer is activated Turn timer off The unit starts and stops frequently There is too much or too little refrigerant in the system Contact a qualified service technician The voltage is too high or too low Contact a qualified service technician Poor heating performance The outdoor temperature is too low Operate system at a lower set temperat...

Страница 12: ...ed Trade Marks of Actron Engineering Pty Limited ActronAir is constantly seeking ways to improve the design of its products Therefore specifications are subject to change without notice Document 9590 8000 Ver 2 Issue Date 06 2022 Refrigerant Trading Authorisation No AU06394 ...

Отзывы: