Troubleshooting - What to look for first.
Indicators of Operation
Operation of the ion indicator lamp:
Turn the unit on and check that the small red/orange lamp is illuminated . The lamp is
located inside the unit and is viewed by looking into the unit through the front grill .
Illumination of the internal lamp verifies that the frequency type ionizer is functioning
properly . The lamp should stay illuminated as long as the unit is turned on .
TROUBLESHOOTING
1. I have plugged in the unit, turned "ON"
the power switch and nothing happens…
what's wrong?
• Make sure the electrical outlet is capable
of providing power to the unit .
• Check the lint screen located at the back
of the machine to ensure that the safety
switch activator clip depresses the safety
switch .
• Check to see if the proper fuse is installed
and that it is serviceable .
• Ensure that the fuse cap is completely
seated and secured in its receptacle .
• Be sure the cord is fully plugged into unit .
2. The fan is operating although the unit
won't produce any ozone… what's
wrong?
• Check the purification plate(s) for
serviceability . If they are cracked
or broken, the plate(s) will require
replacement . Ensure maintenance
procedures required for the purification
plate(s) have been performed according
to the "Maintenance" section (page 11)
of this owner's manual . Order new plates
from your Ativtek Dealer .
• Electrical stainless steel contacts are not
contacting the screen portion of the
purification plate(s) . Inspect the unit for
any loose connections .
• Do not attempt to disassemble the unit,
due to the Limited Warranty of the
product .
3. How am I able to know if the Frequency-
Type Ionizer is working?
• Current models with the FT Ionizer system
have a neon light bulb mounted on the
base of the FT antenna . When the power
switch to the unit is turned ON, the neon
light bulb will illuminate, indicating that
the FT Ionizer is functioning normally
(see above, “Indicators of Operation”) .