ActivePure® Cells must be replaced every twelve (12) months if used continuously, or every two (2) years if
used less than 12 hours per day, even if the UV lamp is still operating.
4. Remove two (2)
thumbscrews.
5. Remove the
ActivePure®
Cell(s) from the
unit.
1. Unlock the ActivePure® Cell
connector by pressing on the
connector’s locking tabs.
2. Pull the connector straight
out to unplug.
3. Unlock and remove the
connector for Cell 2
(if installed).
1
2
1. Unplug unit.
2. Remove the
back cover
screw.
3. Remove back cover. Press the sides to unlatch,
then tilt the bottom out to remove.
4. Remove two (2) thumbscrews securing
the top of the Filter Assembly.
5. Remove the Filter Assembly by pulling back
the top, then lifting up and out
.
REMOVING THE ACTIVEPURE® CELL
REMOVING THE FILTER ASSEMBLY
WARNING: Do not operate the AP3000 II without the Filter Assembly and back cover
properly installed.
Use genuine activTek
replacement parts
only. Parts from
anyone other than
activTek may damage
your unit and void
your warranty.