Do not operate the ActivePure

®

 Surface & Air Guardian without the Filter Assembly and 

Back Cover properly installed.

WARNING

  

REPLACE ACTIVEPURE CELL

 

The CELL indicator will light up if the ActivePure Cell is no longer working. To order a new ActivePure Cell, contact  

 

your sales representative or contact our Customer Service line at 800.572.1446.

 

NOTE:

  The ActivePure Cell should be replaced every one (1) year, even if the unit does not display this message.

 

When the CELL indicator starts flashing, you will need to perform the following operations to reset: 

•  After 1 year of cumulative use, the CELL indicator starts flashing. After the user replaces the new ActivePure Cell  
 

according to the operation steps on page 10 of the manual, long press the RESET button for three seconds  

 

under the power off / standby state, you will hear a beep sound to let you know the reminder has been cleared. 

 

When the CELL indicator starts flashing in red, you will need to perform the following operations to reset: 

•  The CELL indicator flashes in red to remind the user that ActivePure Cell is not properly installed. After  
 

disconnecting the power supply, reinstall ActivePure Cell and check whether the socket is installed properly.  

 

After the installation is successful, there is no need to press the RESET icon, the red light will automatically turn  

 

off. After the above operations, if the indicator remains flashing in red, ActivePure Cell is possibly damaged. In  

 

this case, contact Customer Service at 800.572.1446.

Resetting the Reminders 

The reminders you need to reset are the PERFORM CLEANING and REPLACE ACTIVEPURE CELL indicators (after 
performing maintenance, press the Reset icon and the screen will stop flashing to let you know the reminder has been 
cleared, please see above instructions for each indicator).

GENERAL MAINTENANCE

Unplug the unit before performing any maintenance procedures.

WARNING

Periodic maintenance is required to ensure that your ActivePure Surface & Air Guardian operates properly. The unit will 
display a PERFORM CLEANING reminder when it's time to perform regular maintenance. If you are operating your unit in a 
severely polluted environment, cleaning of the unit, ActivePure Cell, and Filter Assembly should be done more frequently. 
Shown here are basic procedures that should be carried out to keep your unit running at top performance. 

For optimal performance, and to prevent damage not covered by your warranty, install the Optional HEPA Filter. Failure to 
perform routine maintenance could adversely affect the proper function of the unit or cause it to fail prematurely.

NOTE:

  If a unit is returned for repair, and it is determined that neglect of the unit or unauthorized tampering with any  

 

mechanical or electronic component of the unit caused the failure, ActivePure reserves the right to void the  

 

product warranty. This will require the owner to pay for any required repairs.

MAINTENANCE REMINDERS (CONTINUED)

Содержание A1040F

Страница 1: ...x2 READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION...

Страница 2: ...Numbers 00758 00763 Technology ActivePure 2 Cells ozone free HEPA Filter Screen Activated Carbon Filter Carbon Brushes Electrical Input Voltage 100 240 VAC 50 60 Hz External Power Supply DC 24 Volts...

Страница 3: ...om outlet pull firmly on the plug DO NOT unplug by pulling on the cord Always unplug the unit before moving or cleaning or whenever the unit is not in use DO NOT use outdoors or on wet surfaces DO NOT...

Страница 4: ...s device DIRECTIONS FOR USE Plug the cord into a working electrical outlet leaving at least one inch of open area to allow for airflow Please see owner s manual for detailed instructions on using hand...

Страница 5: ...TURES 1 Remove protective packaging 2 Remove unit from shipping carton 3 Remove all protective materials 4 Check for shipping damage and loose or broken parts 5 Read Owner s Manual thoroughly prior to...

Страница 6: ...n 5 Push the A PURE A PURE x2 button twice to set it to A PURE x2 level which will be illuminated on the screen 6 Push the Fan button four times to reach the highest speed 5th level A PURE MODE The un...

Страница 7: ...Back Cover properly installed WARNING PERFORM CLEANING The perform cleaning CLEAN indicator will come on approximately every 180 days for optimal performance it is recommended to perform cleaning on...

Страница 8: ...the indicator remains flashing in red ActivePure Cell is possibly damaged In this case contact Customer Service at 800 572 1446 Resetting the Reminders The reminders you need to reset are the PERFORM...

Страница 9: ...avy particulate This method will extend the life of the Filter Assembly 2 If the Filter Assembly can t be cleaned by vacuuming replace the Filter Assembly Filter Assembly Replacement Contact your sale...

Страница 10: ...duce VOCs and other contaminants NOTE Removing the Optional HEPA Filter Sheet will increase the airflow of the unit UNINSTALLING THE OPTIONAL HEPA FILTER SHEET Unplug the unit before performing any ma...

Страница 11: ...thumbscrews 4 Slide the ActivePure Cell down and out of the unit INSTALLING THE ACTIVEPURE CELLS WARNING Unplug the unit before performing any maintenance procedures Do not operate the ActivePure Surf...

Страница 12: ...the equipment appears unsuccessful Problem Lack of air movement improper placement of the unit Symptom Visual haze of smoke and or particulate remain within the environment Problem Lack of ionization...

Страница 13: ...U S Euro Plug 50108 To order replacement parts contact your sales representative or ActivePure Customer Service for further assistance at 800 572 1446 or email customerservice ActivePure com REPLACEME...

Страница 14: ...medical com To confirm warranty coverage prior to purchasing a product contact ActivePure Customer Service at 800 572 1446 with the serial number located on the back of the unit EXCLUSION OF OTHER WAR...

Страница 15: ...esidential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio c...

Страница 16: ...this product please call Customer Service 1 800 572 1446 or email at customerservice ActivePure com www activepure com ActivePure Medical LLC 14841 Dallas Parkway Suite 500 Dallas TX 75254 800 572 144...

Отзывы: