SETTINGS & ADJUSTMENTS

OPERATION

The ActivePure Surface & Air Guardian can be turned on or off, and adjusted, using the control panel on the front of the unit. 

NOTE:

  If you are operating your central heating and air conditioning fan or other ventilation system continuously, set  

 

the coverage up to the total ventilated indoor area. Otherwise, set the coverage up to the size of the room.

CAUTION

To prevent injury, be sure the power cord is not accessible to small children.

1. 

Take your ActivePure

®

 unit out of the shipping carton 

and remove all protective materials. 

2. 

Place your unit in an appropriate location which 
should be four feet or higher from the ground. Never 
set it on the floor. Place in a location away from 
the HVAC return duct. The rear of the unit requires 
one inch or more of open area to allow unrestricted 
airflow. 

3. 

Insert the Power Supply Plug into the power 
receptacle on the rear of the unit. Plug the 
appropriate cord into the Power Supply and into a 
working electrical outlet. 

4. 

Push the Power button once to turn the unit on. 

5. 

Push the A-PURE/A-PURE x2 button twice to set it 
to A-PURE x2 level which will be illuminated on the 
screen. 

6. 

Push the Fan + button four times to reach the highest 
speed (5th level). 

• 

A·PURE MODE:

 The unit’s display shows the 

fan speed (low to high) and A·PURE to indicate 
that the ActivePure

 

Cell and ionization are both 

functioning normally. 

• 

A·PURE x2 MODE:

 A·PURE x2 lights up, indicates 

that (2) ActivePure Cells and ionization are both 
functioning normally. 

• 

ION MODE: 

Ion lights up, indicates only ionization  

is functioning.

• 

CLEAN:

 Clean illuminates when cleaning is 

required.

• 

RESET:

 Clears the maintenance reminders after 

performing routine maintenance.

• 

CELL: 

The Cell light will flicker when it is time to 

replace your ActivePure Cell. 

For best results, run your ActivePure Surface & Air 
Guardian 24 hours a day, 7 days a week, giving you  
the benefits of ActivePure day and night.

  

POWER 

(STAND BY)

 

 

Turns the unit ON and OFF. 

  

FAN UP/FAN DOWN 

 

Adjusts the five speed fan.

  

A·PURE/A·PURE x2 

 

Toggles the unit between A·PURE Mode  

 

(ActivePure and Ionization) and A·PURE x2  

 

Mode (2 ActivePure Cells and Ionization).

 

REMINDER RESET

 

 

Clears the maintenance reminders after  

 

performing routine maintenance.

Power ON/OFF

Reminder Reset

Fan UP

Fan 

DOWN

A·PURE / 

A·PURE x2

x2

x2

Содержание A1040F

Страница 1: ...x2 READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION...

Страница 2: ...Numbers 00758 00763 Technology ActivePure 2 Cells ozone free HEPA Filter Screen Activated Carbon Filter Carbon Brushes Electrical Input Voltage 100 240 VAC 50 60 Hz External Power Supply DC 24 Volts...

Страница 3: ...om outlet pull firmly on the plug DO NOT unplug by pulling on the cord Always unplug the unit before moving or cleaning or whenever the unit is not in use DO NOT use outdoors or on wet surfaces DO NOT...

Страница 4: ...s device DIRECTIONS FOR USE Plug the cord into a working electrical outlet leaving at least one inch of open area to allow for airflow Please see owner s manual for detailed instructions on using hand...

Страница 5: ...TURES 1 Remove protective packaging 2 Remove unit from shipping carton 3 Remove all protective materials 4 Check for shipping damage and loose or broken parts 5 Read Owner s Manual thoroughly prior to...

Страница 6: ...n 5 Push the A PURE A PURE x2 button twice to set it to A PURE x2 level which will be illuminated on the screen 6 Push the Fan button four times to reach the highest speed 5th level A PURE MODE The un...

Страница 7: ...Back Cover properly installed WARNING PERFORM CLEANING The perform cleaning CLEAN indicator will come on approximately every 180 days for optimal performance it is recommended to perform cleaning on...

Страница 8: ...the indicator remains flashing in red ActivePure Cell is possibly damaged In this case contact Customer Service at 800 572 1446 Resetting the Reminders The reminders you need to reset are the PERFORM...

Страница 9: ...avy particulate This method will extend the life of the Filter Assembly 2 If the Filter Assembly can t be cleaned by vacuuming replace the Filter Assembly Filter Assembly Replacement Contact your sale...

Страница 10: ...duce VOCs and other contaminants NOTE Removing the Optional HEPA Filter Sheet will increase the airflow of the unit UNINSTALLING THE OPTIONAL HEPA FILTER SHEET Unplug the unit before performing any ma...

Страница 11: ...thumbscrews 4 Slide the ActivePure Cell down and out of the unit INSTALLING THE ACTIVEPURE CELLS WARNING Unplug the unit before performing any maintenance procedures Do not operate the ActivePure Surf...

Страница 12: ...the equipment appears unsuccessful Problem Lack of air movement improper placement of the unit Symptom Visual haze of smoke and or particulate remain within the environment Problem Lack of ionization...

Страница 13: ...U S Euro Plug 50108 To order replacement parts contact your sales representative or ActivePure Customer Service for further assistance at 800 572 1446 or email customerservice ActivePure com REPLACEME...

Страница 14: ...medical com To confirm warranty coverage prior to purchasing a product contact ActivePure Customer Service at 800 572 1446 with the serial number located on the back of the unit EXCLUSION OF OTHER WAR...

Страница 15: ...esidential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio c...

Страница 16: ...this product please call Customer Service 1 800 572 1446 or email at customerservice ActivePure com www activepure com ActivePure Medical LLC 14841 Dallas Parkway Suite 500 Dallas TX 75254 800 572 144...

Отзывы: