12
3 . Remove the two (2) thumb nuts on the top and
bottom side of the ballast to pull ballast from
assembly .
4 . Remove the wires from ballast by pressing a small
screwdriver into the wire release:
• Induct Guardian II - 6 wires
• Induct Guardian III - 8 wires
UPPER (3 terminals)
• Black power wire in BLACK
• White power wire in WHITE
• GREEN is not used
7 . Replace cover and secure with the original four (4) screws .
6 . Place new ballast into original location and secure using the
two (2) nuts removed in step 4 .
5 . To reconnect wiring, insert wire into the corresponding color
connector . Gently pull back after inserting wire to ensure the
wire is properly locked into place .
LOWER (6 terminals)
• 2 Red wires in RED
• 2 Blue wires in BLUE
(Induct Guardian III ONLY)
• 2 Yellow wires in YELLOW
GREEN