6. The circulation water flow of the chiller is indicated in the technology parameter table. This chiller
does not have a water pump, so it needs a pump with an available external filter. Using a pump
without an external filter may cause a water leak or other damage (Fig. 6).
7. Do not put the chiller on its side or upside down as this will cause damage to the chiller. If the
chiller is placed on its side, readjust the unit to its correct upright position and wait 20 minutes
before turning it on (Fig. 7).
ASSEMBLY INSTRUCTIONS
1. Remove the chiller unit and all of the contained hardware from the box and packaging material.
2. Set the chiller unit upright in the desired area on a stable surface ensuring there is at least 1
'
of
clearance around the body (sides, top and back) of the unit.
3. Install the inlet/outlet fittings onto the inflow and outflow threaded sites.
NOTE: If the inflow and outflow fittings are different sizes, typically the larger one is used on the
inflow and the smaller one on the outflow.
4. Attach the desired length of tubing onto each inflow and outflow fitting adapter with the worm
drive hose clamps. The inflow should connect the chiller to an appropriately-sized submersible
water pump such as an Active Aqua Submersible Pump in a reservoir of appropriate capacity (see
attached performance curve chart). The outflow tube should hang freely in the reservoir to re-
introduce the chilled water back into it.
NOTE: The pump must be located below the water reservoir water level. If you wish to place the
unit at the side of the reservoir, you must fill the filtration system with water before turning it on.