www.acti.com
ENR-2000 Series System Administrator’s Manual
52
Setup Event Rules
On
Live
screen, click
Setup
click
Event
tab
select a camera.
1.
Once a device is added to ENR server, the server would provide empty rules with
compatible trigger types for you to configure such as
Motion 1, Motion 2
,
Motion 3
,
DI 1
,
DI 2
,
Network Loss
and
Network Recovery
. Select the
Event Type
, then click
“
Set
”.
2.
Select the trigger type:
Trigger DO
Set the DO to become ON or OFF upon trigger, only the devices supporting DO functions
are available. Check the
“
Enable
” to enable this function, and the device whose
connected DO(s) will be triggered. You may select one DO to be activated after the other
and the duration time between them. Clik
“
OK
” to confirm.