Application Information
Piping Connection To The Units
• The outdoor unit is equipped with two to four sets of flare joints depending on O/D unit model. Refer to table
below for flare joint size and location.
• In the case where gas pipe from the indoor unit does not match the outdoor flare joints, two different flare
joint connectors are provided. The connector should be connected as shown in figure.
No
Flarte Joint Connector
1
3/7” to 1/2” Connector
2
1/2” to 3/8” Connector
Pipe Size mm/(in)
Torque Nm/(ft - Ib)
6.35 (1/4)
18 (13.3)
9.53 (3/8)
42 (31.0)
12.70 (1/2)
55 (40.6)
• Align the center of the piping and tighten the flare nut sufficiently with fingers.
• Finally, tighten the flare nut with the torque wrench until the wrench clicks.
FLARE JOINT
CONNECTOR
FLARE TUBE
INDOOR PIPING
FLARE NUT
SPANNER
TORQUE WRENCH
Содержание A5MSX 20 A
Страница 1: ...DC Inverter Multi Split A5MSX 2009 Models A5MSX 20 A AR A5MSX 25 A AR A5MSX 30 A AR...
Страница 2: ......
Страница 11: ...8 A5MSX 2009 Application Information Model A5MSX25A A5WMX10 20G Model A5MSX25AR A5WMX10 15 20GR...
Страница 12: ...9 A5MSX 2009 Model A5MSX30A A5WMX10 20G Model A5MSX30AR A5WMX10 20GR Application Information...
Страница 48: ...45 A5MSX 2009 Outline and Dimension Indoor Unit Model A5WMX10 15G GR m m n i n o i s n e m i D e t o N...
Страница 49: ...46 A5MSX 2009 Outline and Dimension Indoor Unit Model A5WMX20G GR m m n i n o i s n e m i D e t o N...
Страница 55: ...52 A5MSX 2009 Wiring Diagram Indoor Unit Model A5WMX10 15 20G GR Outdoor Unit Model A5MSX25A AR 70 03 4 088704...
Страница 56: ...53 A5MSX 2009 Wiring Diagram Indoor Unit Model A5WMX10 15 20G GR Outdoor Unit Model A5MSX30A AR 70 03 4 089435...