Ultrasonic tester UK1401
Operation Manual
7
ACOUSTIC
CONTROL
SYSTEMS
1
1.2 TECHNICAL SPECIFICATIONS
The main technical specifications of the device are listed in the Table 1
Parameter name
Value
Delay adjustment range, µs
from 2 to 20
Operational frequency, kHz
50
Measurement base, mm
150±1
Indication discreteness of propagation time of ultrasonic waves, µs
0.1
Indication discreteness propagation velocity of ultrasonic waves, m/s
10
Measurement range of propagation time of longitudinal ultrasonic waves, µs
from 12.5 to 150.0
Measurement range of propagation velocity of longitudinal ultrasonic waves, m/s
from 1 000 to 12 000
Limits of permissible absolute measurement error of propagation time of ultrasonic waves, µs,
where t – measured time value
±(0.01∙t+0.1)
Limits of permissible absolute measurement error of propagation velocity of ultrasonic waves, m/s,
where с – measured velocity value
±(0.012∙с+K
•
с
2
+10),
where K=6,7
•
10
-8
(m/s)
-1
Nominal voltage, V
3.3
Period of continuous operation of the instrument with 80% value of screen brightness, at 25˚С,
working with 6 Hz measurement frequency, min.
16 hours
Overall dimensions of the instrument, mm, max.
235x155x65
Maximum weight of the instrument, max.
450 g
Average time between failures
18,000 hours
Average service life
5
Table 1
Содержание UK1401
Страница 2: ...Ultrasonic tester UK1401 Operation Manual 2 ACOUSTIC CONTROL SYSTEMS...
Страница 41: ...Ultrasonic tester UK1401 Operation Manual 41 ACOUSTIC CONTROL SYSTEMS NOTES...
Страница 42: ...Ultrasonic tester UK1401 Operation Manual 42 ACOUSTIC CONTROL SYSTEMS NOTES...
Страница 43: ...Ultrasonic tester UK1401 Operation Manual 43 ACOUSTIC CONTROL SYSTEMS...