   KAK / KLK 
 

page 9 of 16 

 

 

 

Operation and display elements

 

 

Type UB / UC 

– relay output 

 

* The relay S2 only at type UC (2x relay)

 

 
 

Function indicator 

 

 

LED yellow  

 output relay S1 switched on 

 

 

LED yellow  

 output relay S2* switched on 

 

 

Configuration jumper 

 

CH 1   

 

 

Safety function channel 1 (CH1)  

 

Maximum safety    

 

= jumper plugged   NO 

– normally open 

 

Minimum safety    

 

= jumper open    

NC 

– normally closed 

 

CH 2   

 

 

Safety function channel 2 (CH2)  

 

Maximum safety    

 

= jumper plugged   NO 

– normally open 

 

Minimum safety    

 

= jumper open    

NC 

– normally closed 

 

s  

 

 

 

Relay function output relay S1 

 

Limit value function CH1 = Jumper open   

OFF 

 

Two-position control 

s  = Jumper plugged  ON 

 

 

 

 

 

 

 

 

 

 

 

       

At two-position-control 

s both jumper for the safety function    

 

 

 

 

 

   

channel 1 and channel 2 (CH1 and CH2) must be set identically 

 
Adjustment trimmer 

 

Fine adjustment of the response sensitivity within the sensitivity range. 

 

A turn to the left leads to a switching reaction at the output relays at a higher liquid resistance resp. lower 
conductivity. 

 

For adjustment proceed like follows (Safety function 

– Maximum safety – NO): 

 

Liquid must create an electrically conductive connection between measuring and reference electrode 

 

Turn adjustment trimmer to the right (clockwise), till the output switches off 

– LED off 

 

Turn adjustment trimmer to the left (counterclockwise), till the output switches on 

– LED on 

 

Turn adjustment trimmer by an additional half turn to the left (counterclockwise) 

 

Type GA 

– PNP switching output

 

 

Function indicator 

 

 

LED red 

 PNP switching output active 

 
Configuration jumper 

 

Safety function 

 

Maximum safety   = Inv. 

 

Minimum safety   = Norm.

 

 
Adjustment trimmer 

 

Fine adjustment of the response sensitivity within the sensitivity range. 

 

A turn to the right leads to a switching reaction at the output relays resp. PNP switching output at a higher liquid 
resistance resp. lower conductivity. 

 

For adjustment proceed like follows (Safety function 

– Maximum safety – inv.): 

 

Liquid must create an electrically conductive connection between measuring and reference electrode 

 

Turn adjustment trimmer to the left (counterclockwise), till the output switches off 

– LED off 

 

Turn adjustment trimmer to the right (clockwise), till the output switches on 

– LED on 

 

Turn adjustment trimmer by an additional half turn to the right (clockwise) 

 

inv.

+

Vs=22 - 26V DC

PNP-Ausgang

max. 0,5A

M

a

s

s

e

M

in

.

M

a

x

.

norm.

SRAK - 100

O

u

t

1     2    3 

4     5    6 

LED yellow  
output S1 

LED yellow 

output S2* 

Configuration 
jumper 

Adjustment 
trimmer 

LED red 

output 

Adjustment 

trimmer 

Jumper for 
safety function 

Содержание KAK

Страница 1: ...for pumps in pipelines for two position control in plants Wide application range for process temperatures from 40 C to 100 C for process pressures from 1 bar to 10 bar materials for aggressive filling...

Страница 2: ...de Eggenfelden Germany KAK KLK page 2 of 16 Index Application field 3 Function 3 4 5 Safety notes 6 Installation 6 7 Maintenance 7 Repair 7 Electrical connection 8 Operation and display elements 9 Tec...

Страница 3: ...ed by the integrated electronic is than applied either between the electrode rods or between the electrode rods and the metallic wall of the container resp pipe that is connected to the metallic proce...

Страница 4: ...underrun no liquid connection between measuring and reference electrode REF or the power supply fails For both channels CH1 and CH2 the safety function can be set separately This can be carried out b...

Страница 5: ...nnection between electrode CH1 and reference electrode REF or the power supply fails Minimum safety The output signal switches off if the switching level is underrun no liquid connection between elect...

Страница 6: ...uction of the device and to the resulting dangers The sensors may not be used as sole device for prevention of dangerous conditions in machines and plants Using the device in a manner that does not fa...

Страница 7: ...d by that way that in a empty pipe also in the case of liquid residues the electrically conductive liquid connection between electrode and wall resp between the two electrode rods can disconnect Other...

Страница 8: ...circuit Due to this the installation of a fine protection is not necessary Inductive loads at the relay contacts e g auxiliary contactors or magnetic vents may only be used with a free wheeling diode...

Страница 9: ...e connection between measuring and reference electrode Turn adjustment trimmer to the right clockwise till the output switches off LED off Turn adjustment trimmer to the left counterclockwise till the...

Страница 10: ...ry II acc to DIN EN 61010 1 Protection classification II double or reinforced insulation Isolation voltage 1kV auxiliary power PNP switching output to electrode circuit Relay output UB UC Function 1x...

Страница 11: ...re range 1 bar 10 bar Weight Terminal enclosure steel 0 5 kg Terminal enclosure PTFE POM PP 0 2 kg Electrode rod diameter 4 mm 0 1 kg 1000 mm Electrode rod diameter 8 mm 0 4 kg 1000 mm Torque strength...

Страница 12: ...ACS Control System GmbH www acs controlsystem de info acs controlsystem de Eggenfelden Germany KAK KLK page 12 of 16 Dimension drawing KAK KAK _ _1G12_ _ _ _ KAK _ _2G10_ _ _ _ KAK _ _3G15_ _ _ _...

Страница 13: ...ACS Control System GmbH www acs controlsystem de info acs controlsystem de Eggenfelden Germany KAK KLK page 13 of 16 Dimension drawing KLK KLK _ _2G10_ _ _ _ KLK _ _1G12_ _ _ _ KLK _ _3G15_ _ _ _...

Страница 14: ...ACS Control System GmbH www acs controlsystem de info acs controlsystem de Eggenfelden Germany KAK KLK page 14 of 16 Dimension drawing KLK KLK _ _2D40_ _ _ _ KLK _ _1D25_ _ _ _ KLK _ _3D50_ _ _ _...

Страница 15: ...ontrolsystem de Eggenfelden Germany KAK KLK page 15 of 16 BEFC 62 for KLK DN25 BEFB 62 for KLK DN40 BEFA 62 for KLK DN50 acc to DIN 11851 acc to DIN 11851 acc to DIN 11851 SEM12 for KLK G1 2 SEM10 for...

Страница 16: ...value Reference electrode REF process connection Process connection material CrNi steel medium contact G12 Thread ISO 228 1 G 1 rod G10 Thread ISO 228 1 G 1 2 rod G15 Thread ISO 228 1 G 1 3 rod D25 Da...

Отзывы: