   KAK / KLK 
 

page 8 of 16 

 

 

 

Electrical connection

 

 

The electrical connection of the device must be carried out according to the respective country specific 
standards. Incorrect installation or adjustment could cause applicationally conditioned risks. 

 

Use only suitable cables with max. 25 

 per wire, that fulfills the requirements e.g. regarding temperature, 

resistance or laying at the place of installation. 

 

The cable gland is suitable for cable diameters from 4 to 10 mm. After installation of the cable the cable gland 
must be fix screwed to ensure the tightness of the connection housing. 

 

For inauguration it is suggested to switch off all connected control devices to avoid unintended control actions. 
 
 

Version UB / UC with relay output 

 

Power supply input, electrode circuit and the two relay outputs are safe galvanically isolated from each other. 

 

Due to the integrated wide range power supply, for connection to supply voltages from 20...253V AC / DC, the 
filling level limit switch is suitable for using in all common energy supply networks. 
The connection is reverse polarity protected. 

 

A fuse is integrated internally at the power supply circuit. Due to this the installation of a fine protection is not 
necessary. 

 

Inductive loads at the relay contacts, e.g. auxiliary contactors or magnetic vents may only be used with a free-
wheeling diode or a RC protection circuit to avoid high voltage peaks. 
 

Version GA with PNP switching output 

 

The power supply voltage and the PNP switching output are galvanically separated from the electrode circuit. 

 

The power supply voltage may not exceed 27 V to avoid damage of the electronic.  
The power supply voltage connection is polarity protected. 

 

The load at the PNP switching output will be connected contactless and by this bounce-free to the positive 
terminal of the power supply voltage by a semiconductor switch. At activated switching state a positive signal 
near power supply voltage is produced at the terminal Out. 
At deactivated switching state and at failure of power supply voltage the semiconductor switch is shut off. 
The PNP switching output is current limited to 0,5 A. 

 

Inductive loads at the PNP switching output, e.g. relays or contactors may only be used with a free-wheeling 
diode or a RC protection circuit to avoid high voltage peaks.

 

 
 

 

 

 

  Version UB / UC  with relay output   

 

 

  Version GA with PNP switching output 

 

 

 

 

 

 terminal occupation  

 

 

 

 

 

  terminal occupation   

 

  plug occupation 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
* The relay S2 is only available at the version UC (wide range power supply with 2x relay output)

 

1(brown) 

3(blue) 

+V

-V

Plug M12 x 1 

Out 

4(black) 

Содержание KAK

Страница 1: ...for pumps in pipelines for two position control in plants Wide application range for process temperatures from 40 C to 100 C for process pressures from 1 bar to 10 bar materials for aggressive filling...

Страница 2: ...de Eggenfelden Germany KAK KLK page 2 of 16 Index Application field 3 Function 3 4 5 Safety notes 6 Installation 6 7 Maintenance 7 Repair 7 Electrical connection 8 Operation and display elements 9 Tec...

Страница 3: ...ed by the integrated electronic is than applied either between the electrode rods or between the electrode rods and the metallic wall of the container resp pipe that is connected to the metallic proce...

Страница 4: ...underrun no liquid connection between measuring and reference electrode REF or the power supply fails For both channels CH1 and CH2 the safety function can be set separately This can be carried out b...

Страница 5: ...nnection between electrode CH1 and reference electrode REF or the power supply fails Minimum safety The output signal switches off if the switching level is underrun no liquid connection between elect...

Страница 6: ...uction of the device and to the resulting dangers The sensors may not be used as sole device for prevention of dangerous conditions in machines and plants Using the device in a manner that does not fa...

Страница 7: ...d by that way that in a empty pipe also in the case of liquid residues the electrically conductive liquid connection between electrode and wall resp between the two electrode rods can disconnect Other...

Страница 8: ...circuit Due to this the installation of a fine protection is not necessary Inductive loads at the relay contacts e g auxiliary contactors or magnetic vents may only be used with a free wheeling diode...

Страница 9: ...e connection between measuring and reference electrode Turn adjustment trimmer to the right clockwise till the output switches off LED off Turn adjustment trimmer to the left counterclockwise till the...

Страница 10: ...ry II acc to DIN EN 61010 1 Protection classification II double or reinforced insulation Isolation voltage 1kV auxiliary power PNP switching output to electrode circuit Relay output UB UC Function 1x...

Страница 11: ...re range 1 bar 10 bar Weight Terminal enclosure steel 0 5 kg Terminal enclosure PTFE POM PP 0 2 kg Electrode rod diameter 4 mm 0 1 kg 1000 mm Electrode rod diameter 8 mm 0 4 kg 1000 mm Torque strength...

Страница 12: ...ACS Control System GmbH www acs controlsystem de info acs controlsystem de Eggenfelden Germany KAK KLK page 12 of 16 Dimension drawing KAK KAK _ _1G12_ _ _ _ KAK _ _2G10_ _ _ _ KAK _ _3G15_ _ _ _...

Страница 13: ...ACS Control System GmbH www acs controlsystem de info acs controlsystem de Eggenfelden Germany KAK KLK page 13 of 16 Dimension drawing KLK KLK _ _2G10_ _ _ _ KLK _ _1G12_ _ _ _ KLK _ _3G15_ _ _ _...

Страница 14: ...ACS Control System GmbH www acs controlsystem de info acs controlsystem de Eggenfelden Germany KAK KLK page 14 of 16 Dimension drawing KLK KLK _ _2D40_ _ _ _ KLK _ _1D25_ _ _ _ KLK _ _3D50_ _ _ _...

Страница 15: ...ontrolsystem de Eggenfelden Germany KAK KLK page 15 of 16 BEFC 62 for KLK DN25 BEFB 62 for KLK DN40 BEFA 62 for KLK DN50 acc to DIN 11851 acc to DIN 11851 acc to DIN 11851 SEM12 for KLK G1 2 SEM10 for...

Страница 16: ...value Reference electrode REF process connection Process connection material CrNi steel medium contact G12 Thread ISO 228 1 G 1 rod G10 Thread ISO 228 1 G 1 2 rod G15 Thread ISO 228 1 G 1 3 rod D25 Da...

Отзывы: