BA 0722 

KAK / KLK 

Filling level limit switch 

 

for conductive filling level supervision 
in electrical conductive liquids

 

Detects up to two limit values 

 

Useable 

 

for filling level resp. limit value detection in liquid container 

 

as overflow protection in container 

 

as dry run protection for pumps in pipelines 

 

for two-position-control in plants 

 

Wide application range 

 

for process temperatures from -40 °C to +100 °C 

 

for process pressures from -1 bar to +10 bar 

 

materials for aggressive filling liquids 

 

Measuring range adjustable up to 200k

 resp. 5µS/cm

 

 

Wide range power supply from 20 to 253V AC and DC 

 

Relay output or PNP switching output 

 

 

 

 

[email protected] 
www.acs-controlsystem.de 

+49 8721 / 9668-0

 

ACS Control-System GmbH

 

Lauterbachstr. 57 

D- 84307 Eggenfelden  

 

FEEL FREE TO 

CONTACT  US

 

 

 

Содержание KAK

Страница 1: ...for pumps in pipelines for two position control in plants Wide application range for process temperatures from 40 C to 100 C for process pressures from 1 bar to 10 bar materials for aggressive filling...

Страница 2: ...de Eggenfelden Germany KAK KLK page 2 of 16 Index Application field 3 Function 3 4 5 Safety notes 6 Installation 6 7 Maintenance 7 Repair 7 Electrical connection 8 Operation and display elements 9 Tec...

Страница 3: ...ed by the integrated electronic is than applied either between the electrode rods or between the electrode rods and the metallic wall of the container resp pipe that is connected to the metallic proce...

Страница 4: ...underrun no liquid connection between measuring and reference electrode REF or the power supply fails For both channels CH1 and CH2 the safety function can be set separately This can be carried out b...

Страница 5: ...nnection between electrode CH1 and reference electrode REF or the power supply fails Minimum safety The output signal switches off if the switching level is underrun no liquid connection between elect...

Страница 6: ...uction of the device and to the resulting dangers The sensors may not be used as sole device for prevention of dangerous conditions in machines and plants Using the device in a manner that does not fa...

Страница 7: ...d by that way that in a empty pipe also in the case of liquid residues the electrically conductive liquid connection between electrode and wall resp between the two electrode rods can disconnect Other...

Страница 8: ...circuit Due to this the installation of a fine protection is not necessary Inductive loads at the relay contacts e g auxiliary contactors or magnetic vents may only be used with a free wheeling diode...

Страница 9: ...e connection between measuring and reference electrode Turn adjustment trimmer to the right clockwise till the output switches off LED off Turn adjustment trimmer to the left counterclockwise till the...

Страница 10: ...ry II acc to DIN EN 61010 1 Protection classification II double or reinforced insulation Isolation voltage 1kV auxiliary power PNP switching output to electrode circuit Relay output UB UC Function 1x...

Страница 11: ...re range 1 bar 10 bar Weight Terminal enclosure steel 0 5 kg Terminal enclosure PTFE POM PP 0 2 kg Electrode rod diameter 4 mm 0 1 kg 1000 mm Electrode rod diameter 8 mm 0 4 kg 1000 mm Torque strength...

Страница 12: ...ACS Control System GmbH www acs controlsystem de info acs controlsystem de Eggenfelden Germany KAK KLK page 12 of 16 Dimension drawing KAK KAK _ _1G12_ _ _ _ KAK _ _2G10_ _ _ _ KAK _ _3G15_ _ _ _...

Страница 13: ...ACS Control System GmbH www acs controlsystem de info acs controlsystem de Eggenfelden Germany KAK KLK page 13 of 16 Dimension drawing KLK KLK _ _2G10_ _ _ _ KLK _ _1G12_ _ _ _ KLK _ _3G15_ _ _ _...

Страница 14: ...ACS Control System GmbH www acs controlsystem de info acs controlsystem de Eggenfelden Germany KAK KLK page 14 of 16 Dimension drawing KLK KLK _ _2D40_ _ _ _ KLK _ _1D25_ _ _ _ KLK _ _3D50_ _ _ _...

Страница 15: ...ontrolsystem de Eggenfelden Germany KAK KLK page 15 of 16 BEFC 62 for KLK DN25 BEFB 62 for KLK DN40 BEFA 62 for KLK DN50 acc to DIN 11851 acc to DIN 11851 acc to DIN 11851 SEM12 for KLK G1 2 SEM10 for...

Страница 16: ...value Reference electrode REF process connection Process connection material CrNi steel medium contact G12 Thread ISO 228 1 G 1 rod G10 Thread ISO 228 1 G 1 2 rod G15 Thread ISO 228 1 G 1 3 rod D25 Da...

Отзывы: