5.3.11.
Read PICC Operating Parameter
This command is used to check the current PICC operating parameter.
Read the PICC Operating Parameter Format (5 bytes)
Command
Class
INS
P1
P2
Lc
Read the PICC Operating Parameter
E0h
00h
00h
20h
00h
Read the PICC Operating Parameter Response Format (6 bytes)
Operating Parameter (1 byte)
Operating
Parameter
Parameter
Description
Option
Bit 0
ISO 14443 Type A
The Tag Types to be detected during
PICC polling.
1 = Detect
0 = Skip
Bit 1
ISO 14443 Type B
1 = Detect
0 = Skip
Bit 2
FeliCa 212 Kbps
1 = Detect
0 = Skip
Bit 3
FeliCa 424 Kbps
1 = Detect
0 = Skip
Bit 4
Topaz
1 = Detect
0 = Skip
Bit 5 - 7
RFU
RFU
RFU
Note: Default value of Operation Parameter = 1Fh.
Response
Class
INS
P1
P2
Le
Data Out
Result
E1h
00h
00h
00h
01h
Operation Parameter