ACM1252U-Y3
– Reference Manual
Version 1.03
www.acs.com.hk
Page 90 of 92
www.acs.com
.hk
5.6.4.
Set the PICC Operating Parameter
This command is used to set the PICC operating parameter of the reader.
Set PICC operation Parameter Command Format (5 bytes)
Command
Class
INS
P1
P2
Le
Set PICC Operation
Parameter
FFh
00h
51h
PICC Operating Parameter
00h
Set PICC operation Parameter Response Format (2 bytes)
Response
Data Out
Result
90h
PICC Operating Parameter
PICC Operating Parameter
Bit
Parameter
Description
Option
7
Auto PICC Polling
To enable the PICC Polling
1 = Enable
0 = Disable
6
Auto ATS Generation
To issue ATS Request whenever an
ISO14443-4 Type A tag is activated
1 = Enable
0 = Disable
5
Polling Interval
To set the time interval between
successive PICC Polling.
1 = 250 ms
0 = 500 ms
4
FeliCa 424 Kbps
The Tag Types to be detected during
PICC Polling.
1 = Detect
0 = Skip
3
FeliCa 212 Kbps
1 = Detect
0 = Skip
2
Topaz
1 = Detect
0 = Skip
1
ISO14443 Type B
1 = Detect
0 = Skip
0
ISO14443 Type A
Note: To detect the
MIFARE tags, the Auto
ATS Generation must be
disabled first.
1 = Detect
0 = Skip