ACM1252U-Y3
– Reference Manual
Version 1.03
www.acs.com.hk
Page 25 of 92
www.acs.com
.hk
5.2.3.2.1. Start Session Data Object
This command is used to start a transparent session. Once the session has started, auto-polling will
be disabled until the session is ended.
Start Session Data Object
Tag
Length (1 byte)
Value
81h
00h
-
5.2.3.2.2. End Session Data Object
This command ends the transparent session. The auto-polling will be reset to the state before the
session has started.
End Session Data Object
Tag
Length (1 byte)
Value
82h
00h
-
5.2.3.2.3. Version Data Object
This command is used to return the version number of the IFD handler.
Version Data Object
Tag
Length (1 byte)
Value
80h
03h
Major Minor Build
5.2.3.2.4. Turn Off the RF Data Object
This command is used to turn off the antenna field.
Turn off RF Field Data Object
Tag
Length (1 byte)
Value
83h
00h
-
5.2.3.2.5. Turn On the RF Data Object
This command is used to turn on the antenna field.
Turn on the RF Field Data Object
Tag
Length (1 byte)
Value
84h
00h
-