Send/receive settings
The current settings can be transmitted to or received from a Bluetooth end device as a configuration
file.
Configurations can be also sent directly from device to device.
At the transmission of settings some parameter are not transmitted.
•
Sensor TAG
•
Storage interval
•
Historical data
•
Diagnose data
•
Factory calibration data
Receive CSV Lin . table
To simplify enormous linearization procedures directly at the device, it is possible to generate a
linearization table as CSV-file and transmit it into the device.
There are different tank calculation programs available to calculate the linearization of a tank form
comfortably.
The CSV-file must match a defined formatting.
•
Comments can be marked with a leading *.
•
Separator Tab
•
Decimal separator dot or comma.
•
First value percentual filling level, second value linearized percent.
•
Table length maximum 40
Example file
**************************************
* Container type: spherical tank
* d=1000,000
* 0% = 0,000
* 100% = 100,000
**************************************
0,00 0,00
3,13 0,29
6,25 1,12
9,38 2,47
12,50 4,30
15,63 6,56
18,75 9,23
21,88 12,26
25,00 15,63
28,13 19,28
31,25 23,19
34,38 27,33
37,50 31,64
40,63 36,10
43,75 40,67
46,88 45,32
50,00 50,00
53,13 54,68
56,25 59,33
59,38 63,90
62,50 68,36
65,63 72,67
68,75 76,81
71,88 80,72
75,00 84,38
78,13 87,74
81,25 90,77
84,38 93,44
87,50 95,70
90,63 97,53
93,75 98,88
96,88 99,71
100,00 100,00
Receive firmwareupdate
The internal software of the device (firmware) can be updated by a new firmware, that could include
functional improvements, functional extensions, new functions or also customer specific modifications.
At the file transmission the safety of the power supply must be ensured. A power fail can lead to a
completely irreversible device failure.