5. Setting up the device
15
Brightness control,
Light
:
Default:
15
The brightness of the display can be adjusted in 16 levels from 00 = very dark to 15 = very
bright via this parameter or alternatively via the navigation keys from the outside. During the
start of the device the level that is deposited under this parameter will always be used, even
though the brightness has been changed via the navigation keys in the meantime.
Assignment (deposit) of key functions,
tASt:
Default:
no
For the operation mode, special functions can be deposited on the navigation keys
[
▲
] [
▼
]
, in
particular this function is made for devices in housing size 48x24mm which do not have a 4th
key (
[O]
-key). If the min/max-memory was activated with
EHtr
, all measured min/max-values
are saved during operation and can be recalled via the navigation keys. The values get lost by
restart of the device. If the threshold value correction
LI.12
or
LI.34
was choosen, the values of the
threshold can be changed during operation without disturbing the operating procedure. With
tArA
the device is tared to zero and saved permanently as offset. The device confirms the
correct taring by showing
ooooo
in the display.
Set.tA
switches into the offset value and can be
changed via the navigation keys
[
▲
] [
▼
]
. Via
totAL
the current value of the totaliser can be
displayed for approx.7 seconds, after this the device changes back on the parameterised
display value. If
tot.rE
is deposited, the totaliser can be set back by pressing of the navigation
keys
[
▲
] [
▼
]
, the device acknowledges this with
ooooo
in the display. The configuration of
EHt.rE
deletes the min/max-memory. Under
ActuA
the measurand is shown for approx. 7
seconds, after this the display returns to the parameterised display value. If
AbS.UA
(absolute
value) was selected, the display shows the value that has been measured since voltage
connection, without consideration of a previous taring. Via selection
L1.1
,
L1.1-2
,
li.1-3
,
l1.1-4
, in case
of 8 switching points
li.1-5
…
li.1-8
, threshold values can be addressed via the navigation keys;
they can be changed digit per digit or taken over by pushing the
[P]
-key. The adjustment is
taken over directly, an excisting limit value monitoring and the current measurement will not be
influenced by this. If
no
is selected, the navigation keys are without any function in the operation
mode.
Display flashing,
FLASH:
Default:
no
A display flashing can be added as additional alarm function either to single or to a combination
of off-limit condition. With
no
, no flashing is allocated.
Parameterisation level
Menu level