background image

SERIES IP220 INDUSTRIAL I/O PACK 

1

2

-BIT HIGH-DENSITY ANALOG OUTPUT MODULE

Access Times (8MHz Clock):

ID PROM Read0

 wait states (250ns cycle).

DAC Channel Data Write0

 wait states (250ns cycle).

DAC Offset/Gain Coeff. Read 0 wait states (250ns cycle).

Control Register Writes0

 wait states (250ns cycle).

APPENDIX

CABLE: MODEL 5025-550-x (Non-Shielded)

MODEL 5025-551-x (Shielded)

Type: Flat Ribbon Cable, 50-wires (female connectors at both

ends). The .-X suffix designates the length in feet (12 feet
maximum). Choose shielded or unshielded cable according to
model number. The unshielded cable is recommended for
digital I/O, while the shielded cable is recommended for
optimum performance with precision analog I/O applications.

Application: Used to connect Model 5025-552 termination panel to

the AVME9630/9660 non-intelligent carrier board A

-D

connectors (Both have 50-pin connectors).

Length: Last field of part number designates length in feet (user-

specified, 12 feet maximum). It is recommended that this length
be kept to a minimum to reduce noise and power loss.

Cable: 50-wire flat ribbon cable, 28 gage. Non-Shielded cable

model uses Acromag Part 2002-211 (3M Type C3365/50 or
equivalent). Shielded cable model uses Acromag Part 2002-261
(3M Type 3476/50 or equivalent).

Headers (Both Ends): 50-pin female header with strain relief.

Header 

- Acromag Part 1004-512 (3M Type 3425-6600 or

equivalent). 

Strain Relief 

- Acromag Part 1004-534 (3M Type

3448-3050 or equivalent).

Keying: Headers at both ends have polarizing key to prevent

improper installation.

Schematic and Physical Attributes: For Non-Shielded cable model,

see Drawing 4501-462. For Shielded cable model, see Drawing
4501-463.

Shipping Weight: 1.0 pound (0.5Kg), packed.

TERMINATION PANEL: MODEL 5025-552

Type: Termination Panel For AVME9630/9660 Boards
Application: To  connect field I/O signals to the Industrial I/O Pack

(IP). 

Termination Panel: 

Acromag Part 4001-040 (Phoenix

Contact Type FLKM 50). The 5025-552 termination panel
facilitates the connection of up to 50 field I/O signals and
connects to the AVME9630/9660 3U/6U non-intelligent carrier
boards (A-D connectors only) via a flat ribbon cable (Model
5025-550-x or 5025-551-x). The A-D connectors on the carrier

board connect the field I/O signals to the P2 connector on each
of the Industrial I/O Pack modules. Field signals are accessed

via screw terminal strips. The terminal strip markings on the
termination panel (1-50) correspond to P2 (pins 1-50) on the
Industrial I/O Pack (IP). Each Industrial I/O Pack (IP) has its
own unique P2 pin assignments. Refer to the IP module manual
for correct wiring connections to the termination panel.

Schematic and Physical Attributes: See Drawing 4501-464.
Field Wiring: 50-position terminal blocks with screw clamps. Wire

range 12 to 26 AWG.

Connections to AVME9630/9660: P1, 50-pin male header with

strain relief ejectors. Use Acromag 5025-550-x or 5025-551-x
cable to connect panel to VME board. Keep cable as short as

possible to reduce noise and power loss.

Mounting: Termination panel is snapped on the DIN mounting rail.
Printed Circuit Board: Military grade FR-4 epoxy glass circuit board,

0.063 inches thick.

Operating Temperature: -40°C to +100°C.
Storage Temperature: -40°C to +100°C.
Shipping Weight: 1.25 pounds (0.6kg) packed.

TRANSITION MODULE: MODEL TRANS-GP

Type: Transition module for AVME9630/9660 boards.
Application:  To  repeat field I/O signals of IP modules A through D

for rear exit from VME card cages. This module is available for
use in card cages which provide rear exit for I/O connections via
transition modules (transition modules can only be used in card
cages specifically designed for them). It is a double-height

(6U), single-slot module with front panel hardware adhering to

the VMEbus mechanical dimensions, except for shorter printed
circuit board depth. Connects to Acromag termination panel

5025-552 from the rear of the card cage, and to
AVME9630/9660 boards within card cage, via flat 50-pin ribbon
cable (cable Model 5025-550-X or 5025-551-X).

Schematic and Physical Attributes: See Drawing 4501-465.
Field Wiring: 100-pin header (male) connectors (3M 3433-D303 or

equivalent) employing long ejector latches and 30 micron gold in
the mating area (per MIL-G-45204, Type II, Grade C).
Connects to Acromag termination panel 5025-552 from the rear
of the card cage via flat 50-pin ribbon cable (cable Model
5025-550-X or 5025-551-X).

Connections to AVME9630/9660: 50-pin header (male) connectors

(3M 3433-1302 or equivalent) employing long ejector latches
and 30 micron gold in the mating area (per MIL-G-45204, Type
II, Grade C). Connects to AVME9630/9660 boards within the
card cage via flat 50-pin ribbon cable (cable Model 5025-550-X
or 5025-551-X). Transition module is inserted into a 6U-size,
single-width slot at the rear of the VMEbus card cage.

Mounting: Transition module is inserted into a 6U-size, single-width

slot at the rear of the VMEbus card cage.

Printed Circuit Board: Six-layer, military-grade FR-4 epoxy glass

circuit board, 0.063 inches thick.

Operating Temperature: -40°C to +85°C.
Storage Temperature: -55°C to +105°C.
Shipping Weight: 1.25 pounds (0.6Kg) packed.

- 12 -

Содержание IP220 Series

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...put Board USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 1994 1996 Acromag Inc Printed in the USA Data and...

Страница 3: ...OUTPUTS 1 0 LOGIC POWER INTERFACE 1 0 5 0 SERVICE AND REPAIR 1 0 SERVICEAND REPAIR ASSISTANCE 1 0 PRELIMINARY SERVICE PROCEDURE 1 0 6 0 SPECIFICATIONS 1 1 GENERAL SPECIFICATIONS 1 1 ANALOG OUTPUTS 1 1...

Страница 4: ...CK SOFTWARE LIBRARY Acromag provides an Industrial I O Pack Software Library diskette Model IPSW LIB M03 MSDOS format to simplify CAUTION SENSITIVEELECTRONICDEVICES O DNOT MN ORSTOREREMSTRONG ELECTROS...

Страница 5: ...upply sourced from the P2 connector The IN OUT configuration of the jumpers for the different supplies is shown in the following table IN means that the pins noted are shorted together with a shorting...

Страница 6: ...ctor of the carrier board AMP 173280 3 or equivalent This provides excellent connection integrity and utilizes gold plating in the mating area Threaded metric M2 screws and spacers are supplied with t...

Страница 7: ...OC Total Number of ID PROM Bytes 17 55 IP220 16 34 IP220 8 CRC 19 to 3F yy Not Used ADDRESS MAPS Table 3 1 IP220 I O Space Address Memory Ma Notes Table 3 1 1 The IP will not respond to addresses that...

Страница 8: ...rred to the output latch and the updated analog output appears at the board s field connector The data of all the channels is simultaneously transferred once per simultaneous trigger from the D A inpu...

Страница 9: ...ously and synchronously to produce desired analog outputs This method is useful for applications that require updating all the channels simultaneously and synchronously Each channel is written to with...

Страница 10: ...esired_Voltage 2048 2 Using equation 2 one can determine the ideal count for any desired voltage within the range For example if it is desired to output a voltage of 5 Volts equation 2 retums the resu...

Страница 11: ...The Transparent Mode allows channels to be updated quickly on an individual basis since data written to the input latch is immediately transfered to the output latch and converted to an updated analo...

Страница 12: ...temAccuracy 0 0 2 5 of 20V SPAN Maximumcorrectederror i e calibrated at 25 C See Note 5 withthe outputunloaded SettlingTime8 u S to within 0 012 for a 20V stepchange load of 5KLIin parallelwith 470 pf...

Страница 13: ...rial I O Pack IP Each Industrial I O Pack IP has its own unique P2 pin assignments Refer to the IP module manual for correct wiring connections to the termination panel Schematic and Physical Attribut...

Страница 14: ...e I I SPACER COMPONENT SIDE OF CARRIERBOARD IPN WE y 6 POPHEAD SCREW ASSEMBLYPROCEDURE THREADEDSPACERSARE PROVIDED IN TWO DEFERENT LENGTHS THESHORTER LENGTH IS FOR USEWOW AWE 3 0 8 8 COPPER SHOWN CHE...

Страница 15: ...coocroco 10 NOLOG COMMON 4 V t A VO DUE TO VOLTAGE DROPS ACROSSNNE LEAD 11151510CE Or NNE WOE R Is ococomooto TNATA NON RESISTN4CE LON 1 nm A SNORT I N K RUN BE CONNECTED Al I I I OUTPUT 10 COLIC LIE...

Страница 16: ...O r 4 5 0 1 4 6 2 P2 46 45 43 42 44 3 9 3 8 3 7 3 6 3 5 3 4 3 3 37 31 7 9 2 8 2 7 2 6 2 5 24 7 3 7 7 21 2 6 19 6 16 15 12 12 9 8 5 3 7 1 I 0 7 764 5 11 0 7 1 1 45 6 2 1014Nre1 TO M O U N D 5 14110 4 P...

Страница 17: ...39 41 4 3 45 4 7 49 0000000000000000000000000 MODELTRANS GP MODULESCHEMATIC 0 1 TOPVIEW FRONTVIEW A 1 2 3 4 8 4 9 5 9 1 2 3 A 8 4 9 5 8 r 2 3 4 0 5 9 1 1 2 3 4 9 5 4 1 A 141644441011 PANEL ACROMAGPAIN...

Страница 18: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: