Acromag, Inc.   Phone: (248) 295-0880   

 Fax: (248) 624-9234                           

- 3 -

                   

 E-mail: [email protected]   

 On-Line: http://www.acromag.com

 

 
 
 

 
 

3

2

1

J4

2

J1

2

2

J2

RT

N

2

3

CO

M

D

D

R

T

T

R

NC

S1

D

D

D

D

T

3

2

1

3

1

3

1

3

1

24V

D

C

J4

1

8

6

7

J2

J1

5

3

4

2 1

J3

J2

J4 J3

2

J1

COM

D

D

COM

CO

M

3

2

R

T

R

COM

G

F1

Vcc

D

D

     EOL
DISABLED

     EOL
DISABLED

3

1

RS-485

SIDE B

24V

D

C

J3

   TX

A  -  B

FAULT

    B

R

S

-485

SI

D

E

 B

1

   TX

B  -  A

R

S

-485

SI

D

E

 A

BAUD
RATE

G W

L2

G

FAULT

    A

FUSE 3AG

0.5A, 250V

Status
LED's

Status
LED's

AC (HI)

1200 OHMS

HOT

POWER

220 OHMS

1200 OHMS

JUMPER PAIR
(ONE SIDE)

     EOL 
ENABLED

EOL Jumpers

Side B (OUT)

     EOL 
ENABLED

EOL Jumpers
Side A (IN)

GROUND

AC (LO)

RS-485

SIDE A

L1
L1

1 - 600    5 - 9600
2 - 1200  6 - 19.2K
3 - 2400  7 - 38.4K
4 - 4800  8 - 76.8K

FIGURE 2

EOL JUMPERS
EQUIVALENT CIRCUIT
(4683 UNITS ONLY)

NETWORK CONNECTIONS

4683-TTM-3F (24VAC)

4683-TTM-1F (115VAC)
4683-TTM-2F (230VAC)

REMOVE THIS SCREW ON EACH

SIDE TO REMOVE COVER

MODEL 4683-TTM-XF REPEATERS
End-of-Line (EOL) Termination Jumper Locations.
Input Power Fuse Location.

NOTE:  4683-TTM-3F UNITS ARE 24VAC POWERED 
DIRECTLY AND DO NOT REQUIRE A SEPARATE
TRANSFORMER.  THESE UNITS CAN SHARE THE
24VAC POWER BUS OR TRANSFORMER THAT IS
POWERING YOUR OTHER RS485 DEVICES. 

Baud Rate
Switches

 

 
 
 
 

Rx

S1

Tx

R

T

D

CO

M

1

R

0

R

1

1

R

0

R

1

T

R

R

T

D

CO

M

R

T

D

CO

M

0

R

ST

1

R

0

R

ST

1

R

0

R

ST

2

1

5

4

3

7

6

8

24V

D

C

24V

D

C

1 2

4

3

5

7

6

8

24V

D

C

24V

D

C

DFT

DFT

DFT

POWER

R

T

D

RT

N

0

ST

RUN

RUN

ST

0

ST

RUN

RUN

ST

acromag

D

S1

NC

R

T

D

RT

N

1

RUN

0

RUN

ST

1

RUN

0

RUN

ST

1

RUN

BAUD

RATE

CO

M

DFT

Acromag

A-N3

DFT

Acromag

A-N5

BAUD

RATE

B-N1

Acromag

B-N3

DFT

Acromag

B-N5

DFT

Acromag

1 - 300    5 - 4800

2 - 600    6 - 9600

3 - 600    7 - 19.2K
4 - 2400  8 - 38.4K

AC

 IN

PU

T

   T

B

 1

R

S

-232C

232 >
485

RS485
FAULT

 TB

 2

R

S

-485

FAULT
    A

   TX
B  -  A

R

S

-485

SI

D

E

 B

FAULT
    B

acromag

POWER

HOST PC

A-N1

RS-485

DFT

Acromag

A-N4

DFT

Acromag

UP TO 4000 FEET

SIGNAL REPEATER

RS-485

OUTPUT
(SIDE B)

Acromag

ANY RS-485 DEVICE

Acromag

B-N4

B-N32

485 >
232

120

A-N2

1 - 600    5 - 9600

2 - 1200  6 - 19.2K

3 - 2400  7 - 38.4K

4 - 4800  8 - 76.8K

R

S

-485

SI

D

E

 A

   TX
A  -  B

B-N2

ANY RS-485 DEVICE

MODEL 4SCC-TTM-1

MODEL 4SCC-TTM-2

MODEL 4683-TTM-XF

A-N32

INPUT
(SIDE A)

RS-485

RS-485

UP TO 4000 FEET

NETWORK SEGMENT 2

NO TERMINATION RESISTOR

UP TO 32

NODES PER 
NETWORK

SEGMENT

NETWORK SEGMENT 1

RS-232

FIGURE 3

SIDE-B EOL TERMINATION
JUMPERS ENABLED

UP TO 32

NODES PER 
NETWORK

SEGMENT

(EXTENDED NETWORK)

MODEL 4683-TTM-X REPEATER

STATION CONFIGURATION

RS232-TO-RS485 SIGNAL CONVERTER

SIDE-A EOL TERMINATION
JUMPERS ENABLED

120 OHM TERMINATION
RESISTOR REQUIRED
AT END OF NETWORK

OR LAST DEVICE ONLY

OPTIONALLY, YOU MAY CONNECT TERMINATION RESISTORS EXTERNALLY
BETWEEN THE RT TERMINALS ADJACENT TO THE NETWORK CONNECTIONS

FOR SIDE A AND SIDE B, BUT THE INTERNAL JUMPERS MUST BE SET TO
DISABLED WHEN USING EXTERNAL TERMINATION.

120 OHM TERMINATION
RESISTOR REQUIRED
THIS END

 

 
 
 

The station configuration drawing of Figure 3 is for general illustration purposes only.  Johnson 
Controls systems customers should instead refer to the Metasys® Network Technical Manual for N2 
Bus Communication, or the  MS/TP Communication Bus Technical Bulletin for wiring connections 
using the 4683-TTM-xF repeater. 
 

 

Содержание 4683-TTM-1F

Страница 1: ...sed through The repeater receives AC power through a three screw terminal strip Input power is fused and isolated Model 4683 TTM 1F units require 115VAC 4683 TTM 2F units require 230VAC and 4683 TTM 3F units require 24VAC COMMUNICATION SPECIFICATIONS Baud Rates DIP switch settings on unit for 600 1200 2400 4800 9600 19 2K 38 4K 76 8K baud rates Only one switch must be closed according to baud rate...

Страница 2: ...and attach 120Ω termination resistors externally between the RT terminals adjacent to the network connections but this can only be used if the trunk bias is applied somewhere else on the network Reference Section 4 4 1 Idle line Fail safe of the TIA Telecommunications systems bulletin application guideline for TIA EIA 485A Setting The Baud Rate The unit includes an 8 position DIP switch S1 along t...

Страница 3: ...N ST 1 RUN BAUD RATE COM DFT Acromag A N3 DFT Acromag A N5 BAUD RATE B N1 Acromag B N3 DFT Acromag B N5 DFT Acromag 1 300 5 4800 2 600 6 9600 3 600 7 19 2K 4 2400 8 38 4K AC INPUT TB 1 RS 232C 232 485 RS485 FAULT TB 2 RS 485 FAULT A TX B A RS 485 SIDE B FAULT B acromag POWER HOST PC A N1 RS 485 DFT Acromag A N4 DFT Acromag UP TO 4000 FEET SIGNAL REPEATER RS 485 OUTPUT SIDE B Acromag ANY RS 485 DEV...

Страница 4: ...TION RED POWER LED B N4 B N5 Ground 230VAC UP TO 32 NODES PER NETWORK SEGMENT B N32 COM SIGNALS AT CONVERTER HOST RED RS485 FAULT LED SIDE A TRANSMIT DIRECTION B TO A A TO B 2 OPTION 230VAC GROUND AC HI AC LO 1 OPTION SET BAUD RATE AT S1 TRANSMIT DIRECTION RS485 TO RS232 AND RS232 TO RS485 DE9 DB25 TO HOST RS232 CONNECTIONS TO HOST COMPUTER HOST PC RED RS485 FAULT LED SIDE B NOTE SIDE A AND SIDE B...