Flue Connec
�
on
General Notes
This appliance may be installed with a roof terminal or a wall terminal.
This appliance may only be used with Balanced Flue (otherwise known as Concentric Flue)
parts as speci
fi
ed by ACR. The ACR speci
fi
ed
fl
ue parts have been approved with the
appliance. If the appliance is installed on non-ACR approved parts, ACR cannot guarantee or
accept any responsibility for the proper and safe working of the appliance. Please check the
latest approved
fl
ue suppliers with ACR prior to purchasing,
The
fl
ue system must be constructed from the appliance upwards, with all joints being fully
locked and sealed using the ACR speci
fi
ed parts.
If installing the
fl
ue renova
�
on kit, the exis
�
ng
fl
ue must be swept & checked for soundness
prior to installa
�
on.
Timber Frame Construc
�
on
Whilst it is possible to install room-sealed appliances in
�
mber frame proper
�
es, great care
needs to be taken to ensure that the
fl
ue assembly does not interfere with the weather
proo
fi
ng quali
�
es of any outer wall which it may penetrate. Before a
�
emp
�
ng this work,
further details need to be referenced, (e.g. “Gas Installa
�
ons in Timber Frame Buildings”
from the GAS SAFE installer publica
�
ons in the UK).
Car Port or Building Extension
Where a
fl
ue terminal is sited within a car port or building extension, it should have at least
two completely open and unobstructed sides. The distance between the lowest part of the
roof and the top of the terminal should be at least 600mm.
Note: A covered passageway should not be treated as a car port. Flues should not be sited in
a covered passageway between proper
ti
es.
Basements, Lightwells and Retaining Walls
Flue terminals should not be sited within the con
fi
nes of a basement area, lightwell or
external space formed by a retaining wall, unless steps are taken to ensure the
products of combus
�
on can disperse safely at all
�
mes. It may be possible to install this
Balanced Flue system in such a loca
�
on provided that it is not sited lower than 1m from the
top level of that area to allow combus
�
on products to disperse safely.
Flue terminals should be sited to ensure total clearance of the combus
�
on products in
accordance with the manual.
When the products of combus
�
on are discharged, they should not cause a nuisance to
adjoining or adjacent proper
�
es and they should be posi
�
oned so that damage cannot occur
to other parts of the building. If the outer wall surface is constructed of combus
�
ble
material, a non-combus
�
ble plate should be
fi�
ed behind the terminal projec
�
ng 25mm
beyond the external edges of the terminal
19
Содержание NEO Electric
Страница 24: ...Examples of possible alterna ve ueing arrangements Contact your local dealer for more informa on 23...
Страница 25: ...Examples of possible alterna ve ueing arrangements Contact your local dealer for more informa on 24...
Страница 26: ...Examples of possible alterna ve ueing arrangements Contact your local dealer for more informa on 25...
Страница 27: ...Examples of possible alterna ve ueing arrangements Contact your local dealer for more informa on 26...
Страница 42: ...Technical Informa on 41...
Страница 44: ...Dimensions NEO3FGAS NEO3PGAS NEO3CGAS NEO3WGAS 43...
Страница 49: ...48...