NOTE: THE PRIMARY DOOR SWITCH IS NOT ADJUSTABLE

 
 
 

 

 

 
 
 
 
 
 
 
 

SWITCH 

DOOR CLOSED 

CHANGES 

TEST PLUG 

PRIMARY 

OPEN 

At ¼ in 

BU TO RD 

SECONDARY 

CLOSED 

At ½ in 

VT to OR 

MONITOR 

OPEN 

At 1 in 

VT to BU 

TO REMOVE THE SECONDARY/MONITOR SWITCH ASSEMBLY:

  

 
1) 

OPEN THE DOOR 

2) 

REMOVE THE 5/16in (10mm) SECURING NUT and SLIDE SWITCH ASSEMBLY OUT 

 
 
 
 
 
 
 

 
 
 
 
 
 
TO REINSTALL AND PROPERLY REPLACE THE DOOR SWITCH ASSEMBLY:

 

 

1) 

WITH THE DOOR OPEN, SLIDE SWITCH BACK INTO SWITCH BRACKET AND 
TIGHTEN THE 5/16in (10mm) NUT. 

 

2) 

USING AN OHMMETER WITH PROBES INSERTED INTO THE VT AND BU WIRES ON 
THE SECONDAYR/MONITOR SWITCH TEST PLUG, ADJUST MONITOR SWITCH TO 
OPERATE WHEN DOOR IS OPEN TO ONE (1) INCH AT THE TOP OF THE DOOR. 

 

NOTE: TIGHTENING ADJUSTMENT SCREW INCREASES THE TRIPPING POINT (>1 inch)  

 
 
 

 

INTERLOCK SWITCH SERVICE 

 

SECURING 

NUT

 

ADJUSTMENT 

SCREW

 

PRIMARY SWITCH 

TEST PLUG

 

SECONDARY/MONITOR 

SWITCH 

TEST PLUG

 

22 

Содержание ARX51 Series

Страница 1: ...to individual Service Manuals or Technical Sheets for information on other specific models MRX51 ARX51 MRX51U MRX52 ARX52 MRX523 16400035 Rev 2 May 2018 This manual is to be used by qualified service technicians only ACP Inc does not assume any responsibility for property damage or personal injury for improper service procedures done by an unqualified person ...

Страница 2: ...rmware Update Procedure 12 Care and Cleaning 13 Oven Construction 14 Component Testing Procedures 20 Interlock Switch Service 22 Service Test Mode 23 Error Code List 26 Microwave Power Test 27 Control Board Wiring 28 Wiring Diagrams Schematics 29 Accessories 37 http services acpsolutions com SERVICE PARTS SUPPORT ...

Страница 3: ...pedwiththepropertools parts testing instruments and the appropriate service information IT IS THE TECHNICIANS RESPONSIBLITY TO REVIEW ALL APPROPRIATE SERVICE INFORMATION BEFORE BEGINNING REPAIRS ComServ Support Center Web Site Telephone Number WWW ACPSOLUTIONS COM 1 866 811 8559 or 319 368 8195 E Mail commercialservice acpsolutions com Recognize Safety Symbols Words and Labels DANGER Immediate haz...

Страница 4: ... high voltage area of the equipmentcompartment Sometypesof failures will leave a charge in these capacitors and the dischargecouldcauseareflexactionwhichcould makeyouinjureyourself 7 Always remember that in the area of the transformer there is HIGH VOLTAGE When the unitisoperatingkeepthisareaclearandfreeof anythingwhichcouldpossiblycauseanarcor ground etc 8 Do not for any reason defeat the interlo...

Страница 5: ...lly designed to heat cook or dry food It is not designed for industrial or laboratory use 7 As with any equipment CLOSE SUPERVISION is necessary when used byCHILDREN 8 See door cleaning instructions 9 DO NOT heat baby bottles inoven 10 Baby food jars shall be open when heated and contents stirred or shaken before consumption in order to avoid burns 11 DO NOT operate this equipment if it has a dama...

Страница 6: ...cian or pacemaker manufacturerabout effects of microwave energy on pacemaker 14 An authorized servicer MUST inspect equipment annually Record all inspections and repairs for future use SAVE THESE INSTRUCTIONS WARNING To avoid risk of fire in the oven cavity a DO NOT overcook food Carefully attend oven when paper plastic or other combustible materials are placed inside the oven to facilitate cookin...

Страница 7: ...tivity USB Wifi Ethernet USB Wifi Ethernet USB Wifi Ethernet USB Wifi Ethernet Control Type 7in 178cm Capacitive 7in 178cm Capacitive 7in 178cm Capacitive 7in 178cm Capacitive Dimensions Cabinet cm in Width 356cm 14in 356cm 14in 356cm 14in 356cm 14in Height 577cm 22 75in 577cm 22 75in 577cm 22 75in 577cm 22 75in Depth includes handle 739cm 29 125in 739cm 29 125in 739cm 29 125in 739cm 29 125in Oven...

Страница 8: ...ruct oven filters Allow access for filters to be cleaned H Install oven on level countertop surface I Outlet should be located so that plug is accessible when oven is in place Oven cord length is 60in 152cm STEP 3 Test Oven Operation J Ensure cooking plate is installed 1 Oven cavity must be cool to touch 2 Place shelf in oven with curve positioned towardthe the front of the oven This ensures prope...

Страница 9: ...7 ...

Страница 10: ...8 ...

Страница 11: ...9 ...

Страница 12: ...10 ...

Страница 13: ...11 ...

Страница 14: ...n press the home button and proceed to program loading 6 Select Software Version 7 Insert the USB flash drive with the new firmware into the USB port 8 A box will appear in the lower portion of the screen Rev xxxx Available Begin Update 9 Press this box to begin firmware update The screen will now display Entering Standby Mode for a few seconds and then the screen will go blank Continue to wait 10...

Страница 15: ...CARE AND CLEANING 13 ...

Страница 16: ...OVEN CONSTRUCTION CAVITY TOP IMPINGEMENT COVER 4 SCREWS TO REMOVE COOKING PLATE MUST BE IN PLACE TO ALLOW AIR FLOW UNDER FOOD 14 ...

Страница 17: ...RY COVER OUT OF POSITION USING SECURING TAB HELD IN WITH HIGH TEMP GASKETS LOOSEN 2 FRONT SCREWS AND REMOVE 2 BACK SECURING TABS MICA ANTENNA COVER REMOVAL AFTER IMPINGEMENT COVER REMOVED ANTENNAS From Inside Cavity NOTE 1000w ovens use one 15 ...

Страница 18: ... POWER SUPPLY BOARD 24VDC PRIMARY SWITCH DOOR SECONDARY MONITOR SWITCH ASSEMBLY HINGE COOLING FANS TRANSFORMER 1 MECHANICAL LIMITER CAVITY THERMAL CUTOUT CAPILLARY STYLE MAGNETRON 1 COOLING FAN RUN CAPACITORS COOLING FAN PLUGS 16 ...

Страница 19: ...OVEN CONSTRUCTION LEFT SIDE MAGNETRON 2 Not used on 1000w ovens CAPACITOR DIODE ANTENNA MOTOR MAIN CONTROL BOARD FUSE FUSE BLOCK COOLING FANS HINGE 17 ...

Страница 20: ...MBER EXHAUST AIR DUCT AUTO TRANSFORMER SNUBBER COOLING FAN RELAY CONVECTION FAN MOTOR WIRING HARNESS PLUG INS TRIAC COOLING FAN CAVITY THERMAL CUTOUT MECHANICAL LIMITER RESET BUTTON HV SYSTEM FUSES 2 TRIACS 2 POWER RELAY TRANSFORMER LEFT Not used on 1000w ovens 18 LINE FILTERS ...

Страница 21: ...RLOCK SWITCH TEST PLUGS FRONT OF OVEN MAIN CONTROL BOARD POWER SUPPLY BOARD 24VDC ANTENNA MOTOR GEARS CAPACITOR DIODE MAGNETRON 2 Not used on 1000w ovens RTD Resistive Thermal Device Aka TEMP SENSOR EXHAUST PLENUM STEAM VENT TUBE 19 ...

Страница 22: ...evice aka Temp Sensor Temperature 70 F 23 9C 350 F 176 7 Approximately 1100Ω 1650Ω Fuses F1 BLN 250V 30A F3 F4 250V 12A CLOSED Continuity Magnetron DISCHARGE CAPACITORS Wires Removed Terminal to Terminal Both Terminals to Chassis 1Ω OPEN Motor Antenna Wires Removed Terminal to Terminal Approximately 12 000Ω 12KΩ Motor Convection Blower With Line Voltage Applied ST2 Connector Unplugged ST1 1 to ST1...

Страница 23: ...lly OPEN Snubber Transformer Relay Wires Removed Terminal to Terminal Normally OPEN 09µf Switch Primary Use Test Plug By Main Board BU to RD Door Open BU to RD Door Closed Resistance Continuity OPEN NOTE When opening door the Primary Switch should ALWAYS activate first Switches Monitor Secondary Use Test Plug with Door Closed VT to BU Monitor Switch VT to OR Secondary Switch Resistance with Door C...

Страница 24: ... AND PROPERLY REPLACE THE DOOR SWITCH ASSEMBLY 1 WITH THE DOOR OPEN SLIDE SWITCH BACK INTO SWITCH BRACKET AND TIGHTEN THE 5 16in 10mm NUT 2 USING AN OHMMETER WITH PROBES INSERTED INTO THE VT AND BU WIRES ON THE SECONDAYR MONITOR SWITCH TEST PLUG ADJUST MONITOR SWITCH TO OPERATE WHEN DOOR IS OPEN TO ONE 1 INCH AT THE TOP OF THE DOOR NOTE TIGHTENING ADJUSTMENT SCREW INCREASES THE TRIPPING POINT 1 in...

Страница 25: ...ay 3 Enter in order 1 3 5 7 9 and the Service Mode is initiated If the PIN Code is not enabled it must be enabled in the User s Options With oven on press the blue menu icon at the bottom of the screen 1 2 Press the blue menu icon and the PIN Code prompt will display 3 Scroll screen to User Options and press it 4 Scroll screen to PIN Code it will say DISABLED underneath and press it 5 Press the ra...

Страница 26: ...ll display Door Cycles Tube Hours Software Version Displays the version of software and firmware installed in the control Press and the following will display SW EE App Magnetron 1 Right Side System can be started and stopped by pressing the Start or Stop icon The current amperage being drawn by the HV system 5 12amps is considered normal Look for consistent reading with Magnetron 2 and Convection...

Страница 27: ...be started by pressing the Start icon NOTE pressing Stop icon will not stop the antenna motors They continue to run until Service Mode is exited DOES NOT OPERATE ON MRX UNITS Antenna Motors draw very low amperage It is normal to have 0 amps displayed Service provider should visible inspect operation RTD Resistive Thermal Devices aka Temp Sensors Press and the current temperature sensed by the RTD ...

Страница 28: ... Replace the Cavity Thermal Cutout NOTE Cutout may trip if subjected to sub freezing temperatures G2 Open Magnetron TCO Board Senses an Open Magnetron TCO Inspect Cooling Fans Operation and Airflow TCO s and Wiring H0 Zero Cross Failure No or Intermittent Voltage at J1 Connector on Main Control Board H2 Invalid System State Main Control Board H3 Invalid EEPROM FLASH Main Control Board I1 Current S...

Страница 29: ...starting water temperature from the ending water temperature to obtain the temperature rise If the temperature rise meets or exceeds the nominal microwave energy rating found on the model serial tag the test is complete If the temperature rise fails to meet the minimum temperature rise test the line voltage to verify it is correct Then repeat steps 1 6 making sure to change the water If the temper...

Страница 30: ...CONTROL BOARD WIRING 28 ...

Страница 31: ...SCHEMATICS DIAGRAMS MRX51 ...

Страница 32: ...MRX51 ...

Страница 33: ...MRX51U ...

Страница 34: ...MRX51U ...

Страница 35: ...MRX52 ...

Страница 36: ...MRX52 ...

Страница 37: ...MRX523 ...

Страница 38: ...MRX523 ...

Страница 39: ... PLATE SHELF CP10 NON STICK LINER KIT TL10R sides door base PANINI GRILL PLATE RGR10 PADDLE PA10 or PA10R narrower LEG KIT LG10 ACCESSORY RACK TS10R STACKING CART SC10R BACK COVER PANEL BC10R 16400035 Rev 2 May 2018 37 ...

Отзывы: