Illustration
Component
Test
Results
Auto Transformer
230 to 0 (Com)……………………….....
208 to 0 ………………………………...….
120 to 0 (not used)……………….…...
Approximately:
38 Ω
35 Ω
25 Ω
Capacitor, Cooling Fan
Motor
Wire to Wire
1.5µf ± 5% 400V 50/60hz
Capacitor, High Voltage
Terminal to Terminal
.88µf ± 3% 2100V 50/60hz
Control Board, Main
See Service Test Mode Section
Control Board, Touch
Screen Display
See Service Test Mode Section
Convection RTD
(Resistive Thermal
Device) aka Temp
Sensor
Temperature:
70°F (23.9C)………………………………..
350°F (176.7)……………………………...
Approximately:
1100Ω
1650Ω
Fuses
F1 - BLN 250V 30A………………………
F3 & F4 250V 12A……………………….
CLOSED/Continuity
Magnetron
DISCHARGE CAPACITORS!
Wires Removed:
Terminal to Terminal…………………..
Both Terminals to Chassis…………..
<1Ω
OPEN (∞)
Motor, Antenna
Wires Removed:
Terminal to Terminal…………………..
Approximately:
12,000Ω (12KΩ)
Motor, Convection
Blower
With Line Voltage Applied & ST2
Connector Unplugged:
ST1-1 to ST1-2……………………………
Motor not running with line voltage
present indicates a failed motor
assembly.
Motor, Cooling Fan
Wires Removed:
BU to BRN………………………………….…
BU to BK……………………………….……..
BK to BRN…………………………….………
Approximately:
200Ω
685Ω
900Ω
COMPONENT TESTING PROCEDURES
Содержание ARX51 Series
Страница 9: ...7 ...
Страница 10: ...8 ...
Страница 11: ...9 ...
Страница 12: ...10 ...
Страница 13: ...11 ...
Страница 15: ...CARE AND CLEANING 13 ...
Страница 30: ...CONTROL BOARD WIRING 28 ...
Страница 31: ...SCHEMATICS DIAGRAMS MRX51 ...
Страница 32: ...MRX51 ...
Страница 33: ...MRX51U ...
Страница 34: ...MRX51U ...
Страница 35: ...MRX52 ...
Страница 36: ...MRX52 ...
Страница 37: ...MRX523 ...
Страница 38: ...MRX523 ...