User's Manual | ACOM 1500 | HF + 6 m Linear Amplifier
Page 36 of 52 | S e c t i o n MAINTENANCE
August 2021
If, after Primary Mains Fuses replacement, the device does not operate normally, we
recommend repair, performed only by a trained service technician.
Contact your ACOM dealer for assistance (see Section
Besides the primary fuses, on the MAINS PCB (inside the amplifier) there are three fuses which
are not
replaced by the user
. They are fuses of the "T" type (time-lag / slow-blow), European size 5x20 mm,
ceramic (or glass) body cartridge, as follow:
•
1 x 0.2 A, 250 V;
•
2 x 2 A, 250 V.
Suitable fuses are:
•
0.2 A, 250 V, e.g.:
-
Littelfuse, PN: 0215-200 (ceramic body cartridge);
-
Littelfuse, PN: 0218.200 (glass body cartridge);
•
2 A, 250V, e.g.:
-
EATON Bussmann, PN: S505-2-R (ceramic body cartridge);
-
Littelfuse, PN: 0218002 (glass body cartridge).
WARNING
Do not replace fuses located inside the amplifier.
Blown internal fuses can be a symptom of a more serious problem, which should be
resolved beforehand. A fault of this type will not occur under normal operating
circumstances.
Replacing internal fuses is a complex and potentially dangerous operation.
For this reason, we recommend this work be carried out only by a trained service
technician.
Contact your ACOM dealer for assistance (see Section
Unauthorized replacement of inside fuses infringes the warranty conditions!
Besides specific national standards, the principal fuses standard applied worldwide is
IEC 60127.
Содержание 1000
Страница 47: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier August 2021 S e c t i o n NOTES Page 47 of 52 NOTES ...
Страница 48: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier Page 48 of 52 S e c t i o n NOTES August 2021 ...
Страница 49: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier August 2021 S e c t i o n NOTES Page 49 of 52 ...
Страница 50: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier Page 50 of 52 S e c t i o n NOTES August 2021 ...