User's Manual | ACOM 1500 | HF + 6 m Linear Amplifier
Page 18 of 52 | S e c t i o n INSTALLATION
August 2021
f)
Main fuses
NOTICE
Make sure you check whether the main fuses installed in your amplifier (see
, Pos. (f)) correspond to your local mains nominal voltage and if
necessary, replace them as described in Section
WARNING
If your amplifier is only fitted with one line (mains) fuse, it is suitable for European
Community ONLY. Your dealer will check that your amplifier is correctly fused before it is
shipped to you. Customers should check with a qualified electrician if the amplifier is to
be used outside the country in which it was purchased.
g)
Power cord
Due to the different standards in different countries, the mains plug is supplied and mounted by the dealer.
He connects to the mains cord end (see
Figure 2-1 Rear panel - Connections
, Pos. (g)) a standard mains supply
plug which meets the Safety Class I unit standard in your country.
The ground lead of the amplifier's power cord is colored yellow with two green stripes and the blue and
brown leads are active. When the amplifier is to be used with only one mains fuse, it is connected in series
with the brown lead, which must be the active. If you have any doubts about the correct way of connecting
the wires, consult your dealer.
h)
Preparation of wall outlet
WARNING
Before connecting the amplifier to your mains supply using a licensed electrician, check
that the supply is correctly wired, and is adequate for power consumption up to
3500 VA. Make certain that the grounding lead is connected properly and that it has a
cross section not less than the cross section of the phase conductor in the wall outlet for
the amplifier.
It is preferable that you use the wall outlet closest to the source. The installation leads should be at least
2
.5 mm² (AWG 1
3 or SWG 15) at operating 200-240 VAC or 100-120 VAC, (recommended values if there are
no stricter requirements by your local standard).
Check that the panel fuse has a free capacity for the additional load from the amplifier as specified in
Sections
7.1.i) Mains Power Consumption
If you connect the amplifier to a different
mains outlet, be sure that you check it, too.
Содержание 1000
Страница 47: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier August 2021 S e c t i o n NOTES Page 47 of 52 NOTES ...
Страница 48: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier Page 48 of 52 S e c t i o n NOTES August 2021 ...
Страница 49: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier August 2021 S e c t i o n NOTES Page 49 of 52 ...
Страница 50: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier Page 50 of 52 S e c t i o n NOTES August 2021 ...