User's Manual | ACOM 1500 | HF + 6 m Linear Amplifier
Page 32 of 52 | S e c t i o n OFF LINE MODE
August 2021
5.
OFF LINE MODE
There are two control functions and 14 information screens available in this state of the amplifier.
You can enable/disable the AUTO-OPERATE feature, and assign the antenna outputs. You can also list the
auto-protection signatures.
The tube is not powered at all (only the micro-controller is active) during these operations.
All menu selections you make are stored in the nonvolatile memory of the amplifier and
are used at the next power-on. If no menu selection is made for 20 seconds, the current
selection is accepted and the function is left automatically.
5.1.
Display Brightness Control
The Brightness can be adjusted only if the display is VFD (Vacuum Fluorescent Display)
type (obsolete since 2015).
Not operative in units furnished with OLED display.
Press the
PREV
+
NEXT
buttons simultaneously and the "Brightne
ss=…" screen will appear on the
bottom
line. Use the
NEXT
button to control the display brightness in steps from 1 to 4.
Briefly press the
PREV
+
NEXT
buttons in order to reach the Auto-operate function (see Section
Operate Enabling and Disabling
), or leave the buttons unused for 20 seconds if you want to accept these
selections.
5.2.
Auto-Operate Enabling and Disabling
When enabled, this function will keep the amplifier in OPERATE mode automatically. The
OPER
button will
be still functional, so you will be able to change to STANDBY and back to OPERATE manually at any time.
The AUTO-OPERATE function will be disabled temporarily when you enter the STANDBY mode but it will be
restored after you return to OPERATE by depressing the
OPER
Press the
PREV
+
NEXT
buttons in order to enable or disable the AUTO-OPERATE feature. The
"Auto Operate = ..." screen will appear on the bottom line. Use the
PREV
button to select OFF or the
NEXT
button to select ON.
Briefly press the
PREV
+
NEXT
buttons again in order to reach the last control function - the Antenna
Outputs Assignment (see Section
). Alternatively, you may leave the buttons
unused for 20 seconds. In any case, the selections made so far will be retained in the amplifier's memory.
Содержание 1000
Страница 47: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier August 2021 S e c t i o n NOTES Page 47 of 52 NOTES ...
Страница 48: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier Page 48 of 52 S e c t i o n NOTES August 2021 ...
Страница 49: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier August 2021 S e c t i o n NOTES Page 49 of 52 ...
Страница 50: ...User s Manual ACOM 1500 HF 6 m Linear Amplifier Page 50 of 52 S e c t i o n NOTES August 2021 ...