9.6.1 Filter element cleaning
Clean the filter element quarterly. A clogged
filter element can cause overheating or pump
failure.
• If the filter element is heavily clogged, wash it with a
neutral detergent. Rinse with water and dry it in the
shade.
• Reassemble the filter element back in place and press in
the filter cover.
• Fix the filter cover by the truss head screw.
9.6.2 Filter element replacement
• Replace the filter element, following the procedure in 1.
Filter element cleaning.
9.6.3 Valve box, diaphragm replacement
1. Undo the truss head
screw.
2. Remove the filter
cover.
3. Remove the filter
element and shake
out the dust by
hand.
1. Undo the four corner
bolts.
2. Remove the overall
cover.
3. If it is hard to remove,
insert a screwdriver.
4. Pull out the bushing
5. Remove the shock.
6. Undo the screws
7. Remove the holder
cover.
8. Insert the magnet support jig in four corners
between magnet and core.
9. Undo the screws
10. Slide the hose
clamp.
11. Pull out the conne-
cting pipe and
remove the valve
box of one side.
Содержание ClarA 19-38
Страница 1: ...Waste water treatment plant ACO ClarA 19 38 24 48 30 60 38 76 48 96 60 100 Operation manual ...
Страница 28: ...28 Operation manual ACO Clara F2 F1 OFF O 0 OFF A C D B ...
Страница 29: ...29 Operation manual ACO Clara 3000 h 27 5mm DT 4 25 No 27 5mm 28mm DT 4 40 No 28mm xxxx H E F G ...
Страница 32: ...32 Operation manual ACO Clara p VACUUM p PRESSURE OFF O 0 OFF A C 1 C 2 B ...
Страница 33: ...33 Operation manual ACO Clara No D H XXXXX F D 1 D 2 E ...
Страница 36: ...36 Operation manual ACO Clara PRESSURE p p VACUUM OFF O 0 OFF A C 1 C 2 B ...
Страница 37: ...37 Operation manual ACO Clara D 75 mm H 170 mm No 909568 No D xxxx H p VACUUM PRESSURE p F D 1 D 2 E ...