MP-200 

 
 

                                       

           

User Manual 

Please read the manual carefully before using

 

 

Содержание Stag Par MP-200

Страница 1: ...MP 200 User Manual Please read the manual carefully before using ...

Страница 2: ...3 3 How To Set The Unit 5 3 1 Control panel 5 3 2 Main Functions 6 4 How to Control the Unit 12 4 1 Master Slave Built In Preprogrammed Function 12 4 2 DMX Controller 12 5 DMX 512 Configurations 14 6 DMX 512 Connections 15 7 Troubleshooting 16 8 Fixture Cleaning 17 ...

Страница 3: ...hile operating as it is fire hazard y Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base y Maximum ambient temperature is Ta 40 DO NOT operate it where the temperature is higher than this y Unit surface temperature may reach up to 85 DO NOT touch the housing bare hand during its operation Turn off the power and allow about 15 minutes ...

Страница 4: ...id vibration and slipping while operating And make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of ...

Страница 5: ...e smooth dimming with wash effect Quad color with flicker free y Voltage AC 100 240V 50 60Hz y Power Consumption 122W y LED 12pcs x 10W CREE LEDs y Fuse T 6 3A y Beam Angle 10 y Dimension 325 x 276x 344mm y Weight 6 6Kgs ...

Страница 6: ...utput the DMX signal to the next fixture by a 3 pin XLR plug cable 4 DMX Input For DMX512 link use 3 pin XLR plug cable to input the DMX signal 5 Microphone Used to receive the Sound to control the fixture 6 Display Used to show the various menus and the selected functions LED 7 MASTER On Master Mode 8 SLAVE On Slave Mode 9 DMX On DMX input present 10 SOUND Flashing Sound activation ...

Страница 7: ...s the MENU button up to when the required one is showing on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute to e...

Страница 8: ...7A ...

Страница 9: ... setup or automatically return to the main functions without any change after one minute To go back to the functions without any change press the MENU button Slave Mode Select the press the ENTER button and the display will blink Use the DOWN and UP button to select the Slave 1 or Slave 2 mode Once the slave mode has been selected press the ENTER button to setup or automatically return to the main...

Страница 10: ...ress the MENU button Dimmer Mode Press the MENU button up to when is showing on the display Pressing the ENTER button and the display will blink Use the DOWN and UP buttons to select the Dimmer Mode 1 Optically Linear or Dimmer mode 2 Square Law or Dimmer mode 3 Inverse Square Law or Dimmer mode 4 S cure mode Once the mode has been selected press the ENTER button to setup or automatically return t...

Страница 11: ...en the lowest and most sensitive Press the ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the functions without any change press the MENU button Blackout mode Select the press the ENTER button and use the DOWN and UP button to select the blackout or normal Press the ENTER button to setup or automatically exit menu mode without any change aft...

Страница 12: ...ally return to the main functions without any change after one minute Manual Test Select the press the ENTER button and use the DOWN and UP button to select Red Green or or strobe press the ENTER button to confirm and use the DOWN and UP button to adjust the value Once select press the ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the last ...

Страница 13: ... will allow you to link 2 fixtures together and operate without a controller In Master Slave mode the first fixture whose DMX input jack has with nothing connect will be master automatically set other units to slave 1 or slave 2 via menu then the first unit will control the others to give an automatic sound activated synchronized light show This function is good when you want an instant show Any f...

Страница 14: ... change the DMX512 address Once the address has been selected press and keep the ENTER button pressed up to when the display stops blinking or storing automatically one minute later To go back to the functions without any change press the MENU button again Please refer to the following diagram to address your DMX512 channel for the first 4 units ...

Страница 15: ...14A 5 DMX 512 Configurations 4 5 7 Channels Mode ...

Страница 16: ...unit to the input of the next unit The cable can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 5 Each lighting unit needs to ...

Страница 17: ...be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may...

Страница 18: ...quency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days ...

Страница 19: ...h the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Страница 20: ...Innovation Quality Performance ...