Show Mode 

To select 

Show Mode

, press the 

ENTER

 button to confirm.  Use the 

UP

/

DOWN

  button to select 

show1, show 2, show 3 

or

 show 4

, press the 

ENTER

 button to store. Press the 

MENU

 button back 

to the last menu or let the unit idle one minute to exit menu mode. 

Slave Mode 

To select 

Slave Mode

, press the 

ENTER

  button to confirm.  Use  the 

UP

/

DOWN

 button to select 

master, slave 1 

or 

slave 2

, press the 

ENTER

 button to store. Press the 

MENU

 button back to the 

last menu or let the unit idle one minute to exit menu mode. 

Sound Sense

 

To select 

Sound Sense

, press the 

ENTER

 button to confirm. Use the 

UP

/

DOWN

 button to adjust 

the value from 

0

 to

 100

, press the 

ENTER

 button to store. Press the 

MENU 

button back to the last 

menu or let the unit idle one minute to exit menu mode. 

 

Display Settings 

Enter menu mode, select 

Display Setting

, press the 

ENTER

 button to confirm, use the 

UP

/

DOWN

 

button to select

 

Display Inverse, Contrast Ratio, Temperature Unit 

or

 Language

.

 

Display Inverse

 

Select 

Display Inverse

, press the 

ENTER

 button to confirm, present mode will blink on the display, 

use the 

UP

/

DOWN

 button to select 

No 

(normal display) or 

Yes

 (inverse display), press the 

ENTER

 

button to store. Press the 

MENU

 button back to the last menu or let the unit idle one minute to 

exit menu mode. 

Contrast Ratio 

Select 

Contrast Ratio

, press the 

ENTER

 button to confirm, present mode will blink on the display, 

use the 

UP

/

DOWN 

button to adjust value from 

0

 to 

30

, press the 

ENTER

 button to store. Press the 

MENU

 button back to the last menu or let the unit idle one minute to exit menu mode. 

 

Temperature Unit 

Select 

Temperature Unit

, press the 

ENTER

  button to confirm, present mode will blink on the 

display, use the 

UP

/

DOWN

 button to select 

 or 

, press the 

ENTER

 button to store. Press the 

MENU

 button back to the last menu or let the unit idle one minute to exit menu mode. 

Language 

Select 

Language

, press the 

ENTER

 button to confirm, present mode will blink on the display, use 

the

 UP

/

DOWN

 button to select 

English

 or 

Chinese

. Press the 

MENU 

button back to the last menu 

 

11A 

Содержание RAYZOR HYBRID XA-100 BSW

Страница 1: ...XA 100 BSW User Manual Please read the instruction carefully before use...

Страница 2: ...Panel 5 4 Gobo and Lamp 6 4 1 Gobos 6 5 How To Set The Unit 7 5 1 Main Function 7 5 2 Home Position Adjustment 14 5 3 Error Information 16 6 Control By Universal DMX Controller 17 6 1 Connection 17 6...

Страница 3: ...ge and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature TA 4...

Страница 4: ...center if needed Disconnect the mains power if the fixture is has not been used for a long time DO use the original packing materials before transporting it again Cautions To prevent or reduce the ri...

Страница 5: ...n 540 Tilt 270 Pan Tilt moving speed adjustable Automatic Pan Tilt correction Easy calibration and maintenance by magnetic home positioning Dimmer Shutter Blackout 0 100 smooth dimming independent shu...

Страница 6: ...output 3 5 Pin XLR socket Weight 12 Kg Dimension 452 290 256mm 3 Description 3 1 Control Panel Front view Rear view 1 2 3 4 5 6 7 1 LED MASTER On Master mode SLAVE On Slave mode SOUND On Sound activa...

Страница 7: ...pin XLR plug cable to link the units together 5 Power In Used to connect to supply power 6 Power out Used to connect to next unit 7 Fuse T 5A Protect the unit from damage of over current 4 Gobo and L...

Страница 8: ...UP DOWN button to choose the submenu press the ENTER button to store and automatically return to the last menu Press the MENU button or let the unit idle one minute to exit menu mode In the event of...

Страница 9: ...gs 1 Hold Yes mode 1 17 No Yes 0 30 English Chinese Fixture Settings mode 2 20 5m 10m 15m Blackout Linear Square Low Inv SQ Law S Curve Show Setting Show1 Show4 Master Slave1 Slave2 0 100 Yes Fixture...

Страница 10: ...ter slave mode Blackout fixture blacks out if DMX signal stops or Hold fixture continues to obey the last command it received Via DMX if DMX signal stops press the ENTER button to store Press the MENU...

Страница 11: ...te to exit the menu mode Mode 1 Optically Linear The increase in light intensity appears to be linear as DMX value is increased Mode 2 Square Law Light intensity control is finer at low levels and coa...

Страница 12: ...io Temperature Unit or Language Display Inverse Select Display Inverse press the ENTER button to confirm present mode will blink on the display use the UP DOWN button to select No normal display or Ye...

Страница 13: ...and DOWN button to adjust the value press the ENTER button to store the fixture will run as the channel value indicates Press the MENU button back to the last menu or exit menu mode idling one minute...

Страница 14: ...et effect to their home positions or No press the ENTER button to store Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode All Reset All Select All press the...

Страница 15: ...ion will blink on the display use the UP DOWN button to offset the value from 128 to 127 press the ENTER button to store Press the MENU button to exit Tilt Tilt home position adjustment Enter offset m...

Страница 16: ...ct Prism press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 128 to 127 press the ENTER button to store Press the MENU butt...

Страница 17: ...amp always has been on over 700 hours please turn off the lamp Memory Initial Fail It appears when the memory IC is damaged CPU B Error CPU C Error CPU D Error They appear when board P C or some wires...

Страница 18: ...ed or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output...

Страница 19: ...e ENTER button to confirm the present address will blinking the display use the UP DOWN button to adjust the address from 001 to 512 press the ENTER button to store Press the MENU button back to the l...

Страница 20: ...087 088 095 096 103 104 111 112 119 120 127 128 135 136 143 144 151 152 159 160 167 168 175 176 183 184 191 192 199 200 207 208 215 216 223 224 231 232 239 PAN TILT MACRO Off Macro 1 Macro 2 Macro 3 M...

Страница 21: ...r5 Color6 Color7 Color8 Color9 Color10 Color11 Color12 Color13 Color14 Color15 Color16 Color wheel indexing Counter Clockwise rotation fast to slow Stop Clockwise rotation slow to fast 8 000 007 008 0...

Страница 22: ...Stop Counter clockwise rotation slow to fast 11 000 007 008 128 129 255 ANGLE FROST Off Angle Frost 12 000 007 008 255 PRISM No effect Prism Effect 13 000 127 128 189 190 193 194 255 R PRISM Index Cou...

Страница 23: ...changing Disable blackout while Gobo changing No function Pan Tilt reset Effect reset No function All reset Enable blackout while Pan Tilt Color Gobo Moving Disable blackout while Pan Tilt Color Gobo...

Страница 24: ...acro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 Macro 16 Macro 17 Macro 18 Macro 19 Macro 20 Macro 21 Macro 22 Macro 23 Macro 24 Macro 25 Macro 26 Macro 27...

Страница 25: ...WHEEL 1 Open Gobo1 1 Gobo1 2 Gobo1 3 Gobo1 4 Gobo1 5 Gobo1 6 Gobo1 7 Gobo1 1 7 shaking Counter Clockwise rotation fast to slow Stop Clockwise rotation slow to fast 11 000 007 008 016 017 025 026 034 0...

Страница 26: ...On slow to fast strobe open Slow open fast close open Slow close fast open open Random strobe Open 18 000 255 DIMMER 0 100 19 000 255 DIMMER FINE 20 000 069 070 079 080 089 090 099 100 109 110 119 120...

Страница 27: ...linked properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB...

Страница 28: ...depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth and use normal g...

Страница 29: ...e provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 Harmonized Standard EN 60598 1 2015 EN 60598 2 17 1989...

Отзывы: