5-
B. Universal DMX controller
When using a universal DMX controller to control the chain of units, you have to set DMX
address by Dip switches from 1 to 9 to make sure all the units will receive its DMX signal.
Please refer to the following diagram to know how to address your DMX 512 system in the
binary code.
DMX address setting by dip-switches
1. Select the channels of DMX controller
2. Dipswitches
Dip-switches
# 1
# 2
# 3
# 4
# 5
# 6
# 7
# 8
# 9
#10
Value
1
2
4
8
16
32
64
128
256
2-light show
• Examples:
Channel 01
:
dip / on : # 1
(
=1
)
Channel 05
:
dip / on : # 1, # 3
(
1+4=5
)
Channel 09
:
dip / on : # 1, # 4
(
1+8=9
)
Channel 13
:
dip / on : # 1, # 3, # 4
(
=13
)
C. Easy Controller (by CA-8)
The easy remote control is used only in master/slave mode. There is
a terminator for connect the easy controller inside the fixture. By
connecting the cable into DMX IN waterproof cable entry gland to
the CA-8 terminator of the first fixture, you will find that the remote
control on the first fixture will control all the other fixtures for Stand