ACME LED-707 Скачать руководство пользователя страница 3

 

2- 

  1. Safety Introductions   

 

 

 

WARNING 

 

 

 

Please keep this User  Manual for future consultation. If you sell the fixture to another 

user, be sure that they also receive this instruction booklet. 

 

Unpack and check carefully there is no transportation damage before using the fixture. 

 

Before  operating,  ensure  that  the  voltage  and  frequency  of  power  supply  match  the 

power requirements of the fixture. 

 

It’s  important  to  ground  the  yellow/green  conductor  to earth  in  order  to  avoid  electric 

shock. 

 

Disconnect main power before servicing and maintenance. 

 

Use safety chain when fixes this fixture. Don’t handle the fixture by taking its head only, 

but always by taking its base. 

 

Maximum ambient temperature is Ta : 40

. Don’t operate it where the temperature is 

higher than this. 

 

In the event of serious operating problem, stop using the fixture immediately. Never try 

to  repair  the  fixture  by  yourself.  Repairs  carried  out  by  unskilled  people  can  lead  to 

damage  or  malfunction.  Please  contact  the  nearest  authorized  technical  assistance 

center. Always use the same type spare parts. 

 

Do not connect the device to any dimmer pack. 

 

Do not touch any wire during operation and there might be a hazard of electric shock. 

 

To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain 

or moisture. 

 

The housing must be replaced if they are visibly damaged. 

 

Do not look directly at the LED light beam while the fixture is on. 

 

There  are  no  user  serviceable  parts  inside  the  fixture.  Do  not  open  the  housing  or 

attempt any repairs by yourself. In the unlikely event your fixture may require service, 

please contact your nearest dealer. 

 

Please read the instructions carefully which includes important 

information about the installation, operation and maintenance. 

Содержание LED-707

Страница 1: ...LED 707 User Manual Please read the instructions carefully before use ...

Страница 2: ...1 TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 Installation 4 How to control the fixture 5 DMX512 Configuration 6 DMX512 Connections 7 Troubleshooting 8 Fixture Cleaning ...

Страница 3: ...erious operating problem stop using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Do not connect the device to any dimmer pack Do not touch any wire during operation and there might be a hazard of elec...

Страница 4: ...he great built in programmed lighting shows triggered by music Please use a 3 pin XLR cable plug when connecting them together It features different pre programmed chase patterns Fan cooled Dimension 194 x 202 x 141 mm Weight 1KG 3 Installation You can install the unit on the truss or ceiling Use clamps to fix the unit to truss Always ensure that the unit is firmly fixed to avoid vibration and sli...

Страница 5: ...r unit DMX start address MUST be set to 001 First DIP switch ON all other are OFF Slave units DMX start address may have any value but NOT 001 example set the first 3 DIP switches to ON 2 light show Dipswitch 10 off means the unit works normally and on means inversion In order to create a great light show you can set dip switch 10 on on any unit that is linking to the master unit to get contrast m...

Страница 6: ...ller 2 Dipswitches Dip switches 1 2 3 4 5 6 7 8 9 10 Value 1 2 4 8 16 32 64 128 256 2 light show Examples Channel 01 dip on 1 1 Channel 05 dip on 1 3 1 4 5 Channel 09 dip on 1 4 1 8 9 Channel 13 dip on 1 3 4 13 C Easy Controller by CA 8 The easy remote control is used only in master slave mode There is a terminator for connect the easy controller inside the fixture By connecting the cable into DMX...

Страница 7: ... Function and Mode functions 5 DMX512 Configuration Blackout Blackout the unit Function 1 Synchronous Strobe 2 Sound Strobe 3 Two light Strobe Chase Select Chase 1 10 Mode Sound Strobe LED OFF Chase LED ON ...

Страница 8: ...he input of the next fixture The cable cannot be branched or split to a Y cable Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 2 The DMX output and input connectors are pass through to maintain the DMX circuit when no power is connected to the fixture 3 At last fixture the DMX cable has to be terminated with a terminator t...

Страница 9: ...e fan does not work 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on conn...

Страница 10: ...or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specificati...

Страница 11: ...10 Innovation Quality Performance ...

Отзывы: