Troubleshooting the Ozone Generator:
NOTE: Only Aclarus authorized personnel can perform this function.
If indicator lights are off, complete the following:
1. Turn Aclarus system OFF.
2. Inspect the fuses to see if they have been tripped.
3. Replace fuses as required and turn system ON.
If the lights turn on, be sure to perform visual system checks:
after one-hour run time
daily for one week following to ensure system operating properly
If light does NOT turn on, there may be a problem with the transformers and/or ozone
generators. Complete the following:
NOTE: Only Aclarus authorized personnel can perform this function.
Turn Aclarus system OFF
Open the Aclarus system electrical box.
Inspect the generators and transformers for signs of
damage.
If damage is noted and fuses or breakers continue to
trip, call your Aclarus representative for service. Do not
try to repair an ozone generator. This is a replacement
component only. The ozone generator component
comes with replacement instructions.
NOTE: Only Aclarus components can be used with the Aclarus system.