27
Water Column Setup and Maintenance
(NOTE: Your system may come with a check valve instead of a water column –(see image left)
below if you are unsure or contact your Aclarus Rep.)
The water column provides protection to the ozone generator and electrical
components, and also gives a visual reference point for monitoring proper suction of the
water and activation of the ozone system.
In order to function properly, the water level in the water column must remain high
enough that the water can be clearly seen in the site line. (See Figure below). If the
water drops below this level, the system will stop drawing ozone into the water, and
instead will begin drawing the surrounding air into the water. This will prevent the water
from being properly treated, and can eventually cause the ozone generator to fail.
Once per month, check the water level in the water column, and add water as
needed.*
To fill the column, follow the instructions below:
1. Unscrew the cap on the pipe on the top of the water column and remove
the cap.
2.
Pour water into the opening until the site line is between ½” and ¾” full of
water.
3. Replace cap.
*Some systems do not have a water column and instead have a back flow “check” valve to prevent
water from entering the electrical components.
A – Unscrew Cap and fill here
B – Add water until sightline shows ½ -
¾ full. Check regularly to ensure it is
always at least ½ full.
Содержание AOWT-7
Страница 9: ...9 System Components...
Страница 10: ...10 NOTE System components and tank may not be exactly as shown...
Страница 47: ...47 Appendix Component Specification Sheets Pumps Specifications...
Страница 48: ...48...
Страница 49: ...49...
Страница 50: ...50 Flow Switch Specifications...
Страница 51: ...51...
Страница 52: ...52 Mazzei Specifications...
Страница 53: ...53 Gas Off 1 Specifications...