![Acer S511P Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/acer/s511p/s511p_service-manual_6248024.webp)
18
Chapter 1
(This is for 120W power supply)
NOTE:
Measure at line input 90 VRMS and maximum load condition
Environmental Requirements
Item
Specifications
Temperature
Operating
+10 ~ +35
°
C
Non-operating
-10 ~ +60
°
C
-20 ~ +60
°
C (Storage package)
Humidity
Operating
20% to 80% RH, non-condensing
Non-operating
20% to 80% RH, non-condensing (Unpacked)
20% to 90% RH, non-condensing (Storage package)
Vibration
Operating (unpacked)
5 ~ 16.2 Hz: 0.38 mm
16.2 ~ 250 Hz: 0.2 G
Non-operating (packed)
5 ~ 27.1 Hz: 0.6 G
27.1 ~ 50 Hz: 0.4 mm
50 ~ 500 Hz: 2 G
Mechanical Specifications
Item
Specification
Weight
One 3.5 FDD and one 3.5 HDD
(without packing)
10.5Kg(Full Configuration)
Dimensions
(main footprint)
390mmx446mmx234mm
Switching Power Supply 120W
Input Frequency
Frequency Variation Range
50Hz
47Hz to 53Hz
60Hz
57Hz to 63Hz
Input Voltage
Variation Range
100 - 120 VRMS
90 - 132 VRMS
200 - 240 VRMS
180 - 264 VRMS
Input Current
Measuring Range
4A
90 - 132 VRMS
3A
180 - 264 VRMS
Output Requirements
Regulation
Current Rating
+5V
+-5%
11A
Содержание S511P
Страница 10: ...4 Chapter 1 12 Pink Microphone in jack 13 orange Headphone out jack Label Icon Color Description ...
Страница 12: ...6 Chapter 1 12 Burgundy Parallel printer port Label Icon Color Description ...
Страница 67: ...Chapter 3 61 5 Disconnect the FDD cable from the FDD then remove the cable from the FDD ...
Страница 71: ...Chapter 3 65 4 Remove the HDD screw soft mount from the HDD case ...
Страница 72: ...66 Chapter 3 ...
Страница 82: ...76 Chapter 4 ...
Страница 88: ...82 Chapter 6 Veriton FP2 Exploded Diagram ...
Страница 89: ...Chapter 6 83 ...
Страница 90: ...84 Chapter 6 ...
Страница 108: ...102 Appendix A ...
Страница 118: ...114 Appendix B ...
Страница 120: ...114 Appendix C ...