Chapter 1
2
Lamp Specification
1.Product Scope
The product is a lamp system consisting of a short arc burner in a reflector, and a lamp
driver.
Lamp type UHP 200W-150W 1.0
Driver type EUC 200V/01 TopValue
2. SYSTEM SPECIFICATIONS
2.1 Driver conditions
See driver specifications for more information
EUC 200V/01
* If the lamp voltage is below 35V continued over 90s, the driver shuts down.
** If the lamp voltage reaches over 140V, the driver shuts down immediately.
2.2 Run-up time
Run-up time to 80% of the stabilised luminous output is < 60s.
2.3 Ignition
2.3.1 Cold ignition
The criterion for reliable ignition is defined as a maximum of three ignition
failures on 30 attempts per amp however none of these ignition failures
may occur subsequently.
During the ignition phase of the lamp (run-up-time), no cooling of the burner
recommended. Cooling of the burner can lead to ignition failure.