112
Chapter 4
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect,
whether a short circuit is suspected, or whether the system is inoperative.
NOTE:
Verify that all attached devices are supported by the computer.
NOTE:
Verify that the power supply being used at the time of the failure is operating correctly. (See “Power
System Check” on page 99.)
Follow procedures below to isolate the failing FRU. Do not isolate non-defective FRU.
1.
Power off the computer.
2.
Visually check them for damage. If any problems are found, replace the FRU.
3.
Remove or disconnect all of the following devices:
T
Non-Acer devices
T
Printer, mouse, and other external devices
T
Battery pack
T
Hard disk drive
T
DIMM
T
CD/DVD-ROM drive
T
PC cards
4.
Power on the computer.
5.
Determine if the problem has been resolved.
6.
If the problem does not recur, reconnect the removed devices one at a time until you find the failed FRU.
7.
If the problem persists, replace the following FRU one at a time. Do not replace a non-defective FRU.
T
System board
T
LCD assembly
SG_Aspire4920_Book.book Page 112 Monday, May 28, 2007 6:49 PM
Содержание Aspire 4920
Страница 10: ...x ...
Страница 50: ...40 Chapter 1 ...
Страница 58: ...48 Chapter 2 ...
Страница 94: ...84 Chapter 3 19 Carefully detach the RTC battery from the SD card slot ...
Страница 105: ...Chapter 3 95 17 Remove the microphones ...
Страница 106: ...96 Chapter 3 ...
Страница 123: ...Chapter 5 113 System Block Diagram System Block Diagram and Connector Locations Chapter 5 ...
Страница 126: ...116 Chapter 5 Switch Setting Short R525 to clear password ...
Страница 130: ...120 Chapter 4 Aspire 4920 Exploded Diagram ...
Страница 139: ...Chapter 4 129 ...
Страница 141: ...131 Appendix A ...
Страница 142: ...Appendix A 132 ...
Страница 148: ...138 Appendix B ...
Страница 150: ...140 Appendix C ...