80
Chapter 4
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect,
whether a short circuit is suspected, or whether the system is inoperative.
Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
NOTE:
Verify that all attached devices are supported by the computer.
NOTE:
Verify that the power supply being used at the time of the failure is operating correctly. (See “Power
System Check” on page 61):
1.
Power-off the computer.
2.
Visually check them for damage. If any problems are found, replace the FRU.
3.
Remove or disconnect all of the following devices:
T
Non-Acer devices
T
Printer, mouse, and other external devices
T
Battery pack
T
Hard disk drive
T
DIMM
T
PC Cards
4.
Power-on the computer.
5.
Determine if the problem has changed.
6.
If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
7.
If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
T
System board
T
LCD assembly
Содержание Aspire 1510 Series
Страница 6: ...VI ...
Страница 36: ...28 Chapter 1 ...
Страница 55: ...Chapter 3 47 Removing the Battery Pack 1 Slide the battery latch 2 Then remove the battery pack ...
Страница 95: ...Chapter 4 87 8 You will see the screen displaying PASS when the system has buit NAPP Master hard disc drive ...
Страница 96: ...88 Chapter 4 ...
Страница 100: ...92 Chapter 6 Exploded Diagram The Base LCD 14 1 15 0 ...
Страница 101: ...Chapter 6 93 Main Board Module ...
Страница 111: ...Chapter 6 103 ...
Страница 118: ...110 Appendix B Audio Jacks microphone Labtec Verse 504 Alwa Mini Microphone No Brand Item Specifications ...
Страница 120: ...112 Appendix C ...
Страница 121: ...www s manuals com ...