Superdryer 62 Owner’s Manual 

 

3

 

 

 

 

Identification: 

 

For future reference, write down the model, serial number, date of purchase and use this 
information whenever corresponding concerning your dehumidifier. 

 

Model Number   

Superdryer 62 

Serial Number 

_____________________________ 

Date of Purchase  _____________________________ 
 

Customer Service: 

 

For additional questions concerning the operation of your dehumidifier, please: 
 

‰

 

Contact your installing contractor 

 

‰

 

Please call ACE at 919-258-3330

 

‰

 

Email:  

[email protected]

 

 

Warning 

120 Volts AC may cause serious injury from electric shock. 

 

1.

 

Disconnect electrical power before servicing or moving 

2.

 

Plug unit only into grounded electrical outlet

 

3.

 

Do not use extension cord

 

4.

 

Do not use plug adapter

 

 

Power Supply:

   

115V, 60 Hz, Single Phase 

Outlet Requirement:  3-Prong 
Circuit Protector: 

 

15 Amp Time Delay Fuse or Circuit Breaker 

 

Principle of Operation 

 
The Superdryer Series Dehumidifier utilizes its integral humidistat to monitor the conditioned 

space.  When the relative humidity goes above the selected set point, the dehumidifier will 
energize.  Air is drawn across an evaporator coil.  The evaporator coil is cooler than the dew 
point of the air so moisture will condense out of the air (below 70

°

F you will actually see ice 

forming on the evaporator coil).  Air is then reheated through the condenser coil and 

distributed back into the room. 
 

Содержание Superdryer 62

Страница 1: ...midifiers I In ns st ta al ll la at ti io on n a an nd d O Op pe er ra at ti io on ns s M Ma an nu ua al l R Re ea ad d a an nd d S Sa av ve e T Th he es se e I In ns st tr ru uc ct ti io on ns s Distributed Exclusively By Manufactured by Air Cleaning Equipment Inc Broadway NC 27505 Phone 919 258 3330 www AirCleaningEquipment com ...

Страница 2: ...um of 12 clearance and the discharge needs a minimum of 48 clearance If the unit is utilized in a narrow room the unit should be positioned so that the inlet and discharge are facing the longest straight runs Do not insert any objects into the inlet or discharge If service is required call a qualified technician All work on unit should be done with the unit off and unplugged Do not use water to cl...

Страница 3: ...e serious injury from electric shock 1 Disconnect electrical power before servicing or moving 2 Plug unit only into grounded electrical outlet 3 Do not use extension cord 4 Do not use plug adapter Power Supply 115V 60 Hz Single Phase Outlet Requirement 3 Prong Circuit Protector 15 Amp Time Delay Fuse or Circuit Breaker Principle of Operation The Superdryer Series Dehumidifier utilizes its integral...

Страница 4: ...mum of 2 hours before turning the unit on Route drain line 3 4 ID tubing on gravity drain 3 8 ID tubing on units with condensate pump to drain or outside of the area Note On units with gravity drain Drain line must have a downward slope to drain Not applicable to units with reservoirs Reference Fig 1 2 De humidistat 7 starts the functioning of the dehumidifier when the humidity is higher than the ...

Страница 5: ...tion Position of Dehumidistat Knob 1 2 3 4 5___________________ Approximate Room Setpoint 70 60 48 35 25 Relative Humidity In OFF the machine will never start In CONT the machine will never stop NOTE Humidistat settings are approximate only For critical applications you may want to confirm actual settings with a psychrometer and adjust according Display Panel Indications Power Indication Red light...

Страница 6: ... coil to avoid damage Warning Do not steam clean refrigerant coils 4 Plug in Unit 5 Test Refrigerant Charge a Confirm compressor is running and allow to run for minimum of 15 minutes i If under 70 F a layer of ice will form on evaporator coils ii If over 70 F a layer of frost or water droplets will form on coil 6 Test Defrost System a Leave unit running for approximately 35 minutes 45 55 minutes T...

Страница 7: ...mp AMPS FULL LOAD AT 80F 60 5 8 FLA POWER CORD 20 GROUNDED PLUG FILTER SIZE 13 5 x 12 Troubleshooting 1 Unit will not operate a Insure unit is plugged in and red power lamp is illuminated b Insure humidistat is set to high enough level to operate c If unit plugged in and red power lamp is off check fuse or breaker for outlet to make sure power is getting to unit 2 If green full light is on a On un...

Страница 8: ...rranty Seller s liability is limited to replacement of defective parts or components and does not include any cost of labor including but not limited to labor to remove and or reinstall any defective part ACE Fral shall not be responsible for loss of use of any product loss of time inconvenience or damage to other equipment or any other indirect or consequential damage with respect to property whe...

Отзывы: