Superdryer 62 Owner’s Manual 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

       

 

Safety Notes: 

 

The Superdryer Series Dehumidifier must always be connected using the grounded 

electrical connection as required from all electrical appliances.  The warranty is voided 

and all responsibility for the operation is born by the owner if non-grounded wiring is 
utilized. 

 

The Superdryer Dehumidifiers must only be maintained and serviced by a qualified 
technician. 

 

The Superdryer Dehumidifiers are designed to be transported and operated in the 

vertical position.  Any other orientation could cause water to come in contact with the 
electrical components.  Remove plug before moving dehumidifier.  If any water may 

have spread throughout unit, the unit should be opened and allowed to dry thoroughly 
before reconnected to electric and restarting. 

 

For proper operation, neither the inlet nor discharge should be positioned against a 

wall.  The inlet requires a minimum of 12” clearance and the discharge needs a 
minimum of 48”

 

clearance.   

 

If the unit is utilized in a narrow room, the unit should be positioned so that the inlet 
and discharge are facing the longest straight runs. 

 

Do not insert any objects into the inlet or discharge.  If service is required, call a 

qualified technician.  All work on unit should be done with the unit “off” and 
unplugged. 

 

Do not use water to clean unit exterior.  Only use a damp cloth with unit unplugged. 

 

Do not use unit as shelf or device to hang clothes.  This could cause damage to unit. 

 

The inlet filter generally needs cleaned once per month.  Check unit on a weekly basis 

to insure that more frequent cleaning is not required. 

 

Pertinent Technical Standards and Regulations: 

The Superdryer dehumidifier has been designed and manufactured to all the following 

European Standards (Norms) and Regulations: 

 

 

MACHINES NORMS (D.P.R., NR. 459 - 24

th 

July 1996) ; 

 

SECURITY REGULATIONS FOR LOW TENSION APPLIANCES 2006/95/CE); 

 

ELECTROMAGNETIC COMPATIBILITY (EMC) – 2004/108/CE. 

 

It is hereby certified that this Dehumidifier

 

conform to the: 

 

IEC Regulations CEI-EN 60335-2-40, CEI-EN 55014-1, 55014-2. 

 

The machine is built according to RoHS European Norms

 

Содержание Superdryer 62

Страница 1: ...midifiers I In ns st ta al ll la at ti io on n a an nd d O Op pe er ra at ti io on ns s M Ma an nu ua al l R Re ea ad d a an nd d S Sa av ve e T Th he es se e I In ns st tr ru uc ct ti io on ns s Distributed Exclusively By Manufactured by Air Cleaning Equipment Inc Broadway NC 27505 Phone 919 258 3330 www AirCleaningEquipment com ...

Страница 2: ...um of 12 clearance and the discharge needs a minimum of 48 clearance If the unit is utilized in a narrow room the unit should be positioned so that the inlet and discharge are facing the longest straight runs Do not insert any objects into the inlet or discharge If service is required call a qualified technician All work on unit should be done with the unit off and unplugged Do not use water to cl...

Страница 3: ...e serious injury from electric shock 1 Disconnect electrical power before servicing or moving 2 Plug unit only into grounded electrical outlet 3 Do not use extension cord 4 Do not use plug adapter Power Supply 115V 60 Hz Single Phase Outlet Requirement 3 Prong Circuit Protector 15 Amp Time Delay Fuse or Circuit Breaker Principle of Operation The Superdryer Series Dehumidifier utilizes its integral...

Страница 4: ...mum of 2 hours before turning the unit on Route drain line 3 4 ID tubing on gravity drain 3 8 ID tubing on units with condensate pump to drain or outside of the area Note On units with gravity drain Drain line must have a downward slope to drain Not applicable to units with reservoirs Reference Fig 1 2 De humidistat 7 starts the functioning of the dehumidifier when the humidity is higher than the ...

Страница 5: ...tion Position of Dehumidistat Knob 1 2 3 4 5___________________ Approximate Room Setpoint 70 60 48 35 25 Relative Humidity In OFF the machine will never start In CONT the machine will never stop NOTE Humidistat settings are approximate only For critical applications you may want to confirm actual settings with a psychrometer and adjust according Display Panel Indications Power Indication Red light...

Страница 6: ... coil to avoid damage Warning Do not steam clean refrigerant coils 4 Plug in Unit 5 Test Refrigerant Charge a Confirm compressor is running and allow to run for minimum of 15 minutes i If under 70 F a layer of ice will form on evaporator coils ii If over 70 F a layer of frost or water droplets will form on coil 6 Test Defrost System a Leave unit running for approximately 35 minutes 45 55 minutes T...

Страница 7: ...mp AMPS FULL LOAD AT 80F 60 5 8 FLA POWER CORD 20 GROUNDED PLUG FILTER SIZE 13 5 x 12 Troubleshooting 1 Unit will not operate a Insure unit is plugged in and red power lamp is illuminated b Insure humidistat is set to high enough level to operate c If unit plugged in and red power lamp is off check fuse or breaker for outlet to make sure power is getting to unit 2 If green full light is on a On un...

Страница 8: ...rranty Seller s liability is limited to replacement of defective parts or components and does not include any cost of labor including but not limited to labor to remove and or reinstall any defective part ACE Fral shall not be responsible for loss of use of any product loss of time inconvenience or damage to other equipment or any other indirect or consequential damage with respect to property whe...

Отзывы: