VII. MAINTENANCE

CAUTION

Both the electrochemical cell and the alkaline batteries used in the 

CAL-101 instrument contain corrosive chemicals.  While it is not 

expected that the chemicals in the cell or alkaline batteries will leak 

during normal operation, it is recommended that both the cell and 

the batteries be removed from the instrument if it is being stored for 

periods longer than one week between use.

VIII. ACCESSORY ITEMS/ PARTS LIST 

The following items and spare parts are available for the CAL-101:

Part Number        

Description 

                           

113-0400-00        

Quick connect outlet fitting, body,  

 

 

   

 

panel 

mount

400-0000-00        

Circuit board for CAL-101  

 

 

 

   

 

Processor

400-0001-00        

Circuit board for CAL-101 Interface 

400-0002-00        

Circuit board for CAL-101 pump  

 

 

   

 

assy

510-0101-00        

Chlorine generation cell, 2 hour,  

 

 

   

 

specify 

ppm

510-0101- 05        

Hydrogen sulfide generation cell, 2  

 

 

 

 

 

 

hour, specify ppm

510-0101- 07        

Hydrogen cyanide generation cell,  

 

 

 

 

 

 

2 hour, specify ppm

510-0101-09        

Hydrogen generation cell, 2 hour,  

 

 

   

 

specify 

ppm

510-0102-00        

BUMP Chlorine generation cell, 2  

 

 

 

 

 

 

hour, specify ppm

510-0102- 05        

BUMP Hydrogen sulfide generation  

 

 

 

 

 

 

cell, 2 hour, specify ppm

510-0102- 07       

 BUMP Hydrogen cyanide  

 

 

 

 

 

 

 

generation cell, 2 hour, specify ppm

510-0102-09        

BUMP Hydrogen generation cell, 2  

 

 

 

 

 

 

hour, specify ppm

730-0101-00        

Hard-body, water proof, padded   

 

 

   

 

accessory 

case

910-0601-00        

Instruction manual, CAL-101

Содержание CAL-101

Страница 1: ...InstructionManual CalibrationGasGenerator AdvancedCalibrationDesigns Inc CAL 101...

Страница 2: ...al Description Page 2 II Start Up Page 4 III Normal Operation Page 5 IV Non Normal Operation Page 6 V Cell Life Page 8 VI Corrections to Volumetric Flow Page 9 VII Maintenance Page 10 VIII Accessory I...

Страница 3: ...can lead to improper calibrations This instrument conforms to the protection requirements of the EC DIRECTIVE 89 336 EEC on Electromagnetic Compatibility EMC in accordance with the provisions of Stat...

Страница 4: ...is produced when the CAL 101 supplies a known amount of current and a known amount of air continuously to the cell Alkaline AA Batteries A set of two fully charged alkaline AA batteries provides 10 12...

Страница 5: ...ed The bump generating cell is equipped with a switch to initiate a bump cycle In this configuration the cell remains in the instrument and automatically turns off after a 30 second bump cycle Deliver...

Страница 6: ...ndicates that 2 hours remain on the cell 1 LED lit indicates less than 12 minutes of calibration time remain These are the normal operating conditions for the CAL 101 Complete equilibrium may take an...

Страница 7: ...the delivery hose This adapter or cup is then placed over the gas sensor Be sure not to restrict or block the delivery hose while the pump is running This method is used for calibrating diffusion typ...

Страница 8: ...corresponding pads on the cell for corrosion and attempt cleaning If the cell has been depleted it should be removed and replaced with a new generating cell Please refer to the section on cell life fo...

Страница 9: ...er minute STP standard temperature and pressure of sea level and 20o C see chart in section VI To trim the flow hold the magnetic screw driver over the flow trim area of the instrument indicated with...

Страница 10: ...plete list of correct cell part numbers please refer to the parts list at the end of this manual To replace the generating cell in the instrument press down firmly on the cell eject button at the top...

Страница 11: ...ilized Note Altitude and Temperature are cumulative i e you must correct for both factors to obtain the most accurate calibration Altitude Correction Table Temperature Correction Table Altitude Correc...

Страница 12: ...t fitting body panel mount 400 0000 00 Circuit board for CAL 101 Processor 400 0001 00 Circuit board for CAL 101 Interface 400 0002 00 Circuit board for CAL 101 pump assy 510 0101 00 Chlorine generati...

Страница 13: ...ation Designs Inc s obligation under this warranty shall be limited to repairing or replacing and returning any product which shall be returned to Advanced Calibration Designs Inc at its manufacturing...

Страница 14: ...tured by Advanced Calibration Designs Inc 2024 W McMillan St Tucson Arizona 85705 USA Phone 520 290 2855 Fax 520 290 2860 Int l Phone 001 520 290 2855 Fax 001 520 290 2860 Web site www GoACD com E mai...

Страница 15: ...2024W McMillanSt Tucson Arizona85705USA Telephone 520 290 2855 Fax 520 290 2860 TollFree 800 737 0223 Email acd goACD com Web www goACD com P N 910 0601 00 AdvancedCalibrationDesigns Inc...

Отзывы: